background image

Alignment Procedure for Otari MX-5050 B-II 

 
 

Set SRL switch to SRL position. 

 
PLAYBACK 
 

1.

 

Set the Reference Flux, and EQ to suit the test tape 

 

2.

 

AZIMUTH 

a.

 

Adjust for 0º ø on oscilloscope (A4 screw) 

 

3.

 

REPRO LEVEL 

a.

 

Play 0VU @ 1kHz and adjust VR106/VR206 for 0VU 

 

4.

 

REPRO EQ 

a.

 

Play ƒ sweep and adjust VR102/VR202 for a flat response (15 ips) 

b.

 

Play ƒ sweep and adjust VR103/VR203 for a flat response (71/2 ips) 

 
 
 
 
 
 
RECORD 
 

1.

 

AZIMUTH 

a.

 

Adjust for 0º ø on oscilloscope (A3 screw) 

 
2.

 

RECORD METER LEVEL 

a.

 

Set the input level controls to maximum 

b.

 

Record 1kHz from a -15dBm source 

c.

 

Adjust the Record Level trimpot for 0VU 

d.

 

Switch to monitor Source 

e.

 

Adjust VR108/208 for 0VU 

 
 
 
3.

 

RECORD LEVEL 

a.

 

Set the Record flux level switch to M (250nW) 

b.

 

Monitor ‘Source’ and set the level to 0VU 

c.

 

Monitor ‘Tape’ and start recording 

d.

 

Adjust the Record Level trimpot for 0VU 

 
 
 