OST iConverter XGT+ User Manual Download Page 1

iConverter

 

XGT+

Plug-in Module User Manual

This User Manual describes the functions of the 

iConverter

 XGT+ Revision 1.  

Product Overview

The 

iConverter

 XGT+ is a 10 Gigabit Ethernet media converter with one 10GBASE-T RJ-45 

port and one pluggable transceiver port that provides copper-to-fiber and copper-to-copper 

media conversion. Copper-to-fiber conversion is achieved with XFP or SFP+ fiber transceivers. 

Copper-to-copper conversion is achieved with a CX4 XFP transceiver.  
The XGT+ supports high-power (power level 4) XFP transceivers, and the latest generation 

of wavelength tunable DWDM XFP transceivers.

Installation Procedure

1) Configure DIP-switches
2) Install Standalone Module and Connect Cables

3) Verify Operation

1) CONFIGURE DIP-SWITCHES
DIP-SWITCH BANK 1

The  location  of  the  DIP-switches  is  shown  in 

 

Figure 1.
The function of DIP-switch Bank is outlined in Figure 2.

Switch

DOWN 

(Default)

UP

SW1

Normal

P1 Loopback Enabled

SW2

Normal

P2 Loopback Enabled

SW3

Normal

P2 Short Range

SW4

Normal

P1 Built-In Self Test (BIST)

Figure 2:  DIP-switch BANK 1 Definitions

SW1 - P1 LOOPBACK “P1-LB”

When this DIP-switch is in the DOWN position (factory default), port P1 loopback is disabled.  

When this DIP-switch is in the UP “P1-LB” position, loopback is enabled on port P1.  When 

enabled, all data received on port P1 is transmitted out port P1 and the connection between 

port P1 and port P2 is interrupted.

NOTE:  For the XFP model, simultaneous loopback of port P1 and port P2 requires the XFP 

transceiver to support  lineside loopback capability.

SW2 - P2 LOOPBACK “P2-LB”

When this DIP-switch is in the DOWN position (factory default), port P2 loopback is disabled.  

When this DIP-switch is in the UP “P2-LB” position, loopback is enabled on port P2.  When 

enabled, all data received on port P2 is transmitted out port P2 and the connection between 

port P2 and port P1 is interrupted.

Page 1

NOTE:  For the XFP model, simultaneous loopback of port P1 and port P2 requires the XFP 

transceiver to support  lineside loopback capability.

SW3 - P2 Short Range

When this DIP-switch is in the DOWN position (factory default), port P2 short range feature 

is disabled.  When disabled, port P2 will support up to 100 meters of CAT 6A cabling.  When 

this DIP-switch is in the UP “P2-SR” position, port P2 will support up to 30 meters of CAT 5E 

or better cabling in a reduced power consumption mode. 

SW4 - P1 BIST (SFP+ Model Only)
When this DIP-switch is in the DOWN position (factory default), port P1 Built-In Self Test is 

disabled.  When this DIP-switch is in the UP “P1-Tst” position, the port will transmit a Pseudo 

Random Bit Sequence (PRBS).  
When two XGT+ converters are connected via port P1 (Port 1 to Port 1), the BIST function is 

supported.  The XGT+ initiating BIST (DIP-switch SW4 UP) will generate and send a PRBS 

pattern out Port 1 to the other module.  The receiving XGT+ will detect a good test pattern 

and return a PRBS acknowledgement test pattern back to the initiating XGT+.
A successful test will produce a green blinking (5Hz) P1 LB LED on the initiating XGT+ and 

a green blinking (1Hz) P1 LB LED on the receiving XGT+.  If the initiating XGT+ does not 

receive a valid response, the P1 LB LED will be blinking amber (5Hz).  When BIST is initiated, 

the traffic received on Port 2 of both converters will be discarded.
If loopback has been initiated, the self diagnostic circuit test DIP-switch will be ignored.  If self 

diagnostic circuit test has been initiated, the loopback DIP-switches will be ignored.

DIP-SWITCH BANK 2

LINK MODES
SW1 and SW2 - LINK MODES
These  DIP-switches  configure  the  different  link  modes  available  on  the  XGT+.  It  is 

recommended to have link modes set to Link Segment (default setting - all DOWN) during 

the initial installation.  After the circuit has been tested and operational, configure the module 

for the desired mode.  Refer to Figure 3 for configuration options.  

SW1

SW2

Function

DOWN

DOWN

Link Segment (default)

UP

DOWN

Asymmetrical Link Propagate P1 to P2

DOWN

UP

Asymmetrical Link Propagate P2 to P1

UP

UP

Symmetrical Link Propagate

Figure 3:  DIP-switch BANK 2 Link Modes

For detailed information on the operation of the different Link Modes, download the application 

note 

iConverter

 Link Modes” available on Omnitron’s web page:

http://www.omnitron-systems.com/downloads_iconverter.php

SW3 and SW4 - RESERVED

These DIP-switches are for factory use only and must always remain in the DOWN (factory 

default) position.