22
Output configuration
6.1
Ports configuration
The first step of the output configuration is to configure the channel size of
the eight output ports. The channel size is equivalent to the channel count
of the connected fixtures to each port:
1.
Open the ports configuration page by selecting “Output
Configuration” on the left side of the web interface of the e:cue Bridge8:
2. Address up to 512 DMX channels by one port.
3.
After configuring all ports, click the “submit” button to save the
configuration.
6.2
Data mapping (Sources configuration)
The second step of the output configuration is to configure the data input.
The e:cue Bridge8 provides two data input sources. For each source,
Source 1
Universe a
Output for Source 1
take channels
starting at offset1
length
Port x
1.
2.
3.