Osram AB447060035 Setup Manual Download Page 1

AB447060035

e:cue SYMPL Core S

Setup Manual 

Our Brand

www.osram.com/ecue

Light is OSRAM

Summary of Contents for AB447060035

Page 1: ...AB447060035 e cue SYMPL Core S Setup Manual Our Brand www osram com ecue Light is OSRAM ...

Page 2: ...ges All dimensions should be verified using an actual part Except for internal use relinquishment of the instructions to a third party duplication in any type or form also extracts as well as exploitation and or communication of the contents is not permitted Lesen Sie die Installationsanleitung vor dem Auspacken des Produktes sorgfältig durch Alle Änderungen vorbehalten Rechtschreibfehler oder and...

Page 3: ...t Update 09 3 General remarks 10 3 1 Transport 10 3 2 Unpacking 10 3 3 Warranty regulations 10 3 4 Maintenance and Repair 10 3 5 Disposal 11 3 6 Support 11 4 Installation 11 4 1 Installation conditions 12 4 2 Mounting process 12 4 3 Ethernet connection 12 4 4 Power supply 13 5 Network configuration 13 5 1 Default network properties 14 5 2 Network configuration with SYMPHOLIGHT 14 5 3 Network confi...

Page 4: ...04 Table of Contents Inhalt 9 Certifications 21 Dimensions Abmessungen 22 ...

Page 5: ...05 English ...

Page 6: ...exclamation mark warns about possible damage of the device itself or connected devices i The information symbol gives general hints and informs about handling and procedures for use of the device 1 2 General security instructions Connect cables and data only when the device is powered down The device must be supplied by a separate certified SELV Class 2 power supply The maximum length of each conn...

Page 7: ...LIGHT shows in small to medium sized shows and controls all available SYMPL Nodes As a user interface it utilizes the Action Pad of SYMPHOLIGHT with all usual web browsers The connection between SYMPL Core S external systems and the Nodes is a standard Ethernet network Shows can be transferred to the SYMPL Core S from a SYMPHOLIGHT server or uploaded from many sources 2 1 Delivery content Delivery...

Page 8: ...USB 2 0 socket 2 3 User interface LEDs The SYMPL Core S has four LEDs The four LEDs show the basic states of the SYMPL Core S LEDs Master Slave Blue This SYMPL Core S is master in a master slave group Yellow This SYMPL Core S is a slave in a master slave group Error Status Green Signals system activity Orange System load reaches 100 Red A system error occurred Restart the system by disconnecting t...

Page 9: ...he Identify button pressed while powering up Status and Test Error light up at first Bootloader mode is signaled by a fast blinking Status LED Release the button now The device stays in bootloader mode to download a new firmware To exit the bootloader mode short press the Identify button again Press the Identify button until Status and Test Error LEDs blink alternating then blink together Releasin...

Page 10: ...very content on page 07 If there is apparent damage to the device or parts are missing from the delivery scope please contact the OSRAM Support service 3 3 Warranty regulations Depending on the product guaranty regulations are of different duration The warranty time is usually noted in the quote and in the order confirmation See Services OSRAM Guarantee at www osram com for details Legal warranty ...

Page 11: ...omer Service Karl Schurz Str 38 33100 Paderborn Germany 49 5251 54648 0 support ecue com 4 Installation The installation of the SYMPL Core S consists of mounting the device connections to e net and to power supply The sequence of cabling is not defined Supply the SYMPL Core S with power after all cabling is completed it starts booting Batteries and technical appliances must not be disposed of with...

Page 12: ...al position 1 Clip the device to the rail from top 2 Gentle pressure is then applied to the top front to snap it in place The SYMPL Core S has been mounted successfully You can also mount the e cue SYMPL Core S on any flat vertical surface Use a 3 to 3 5 mm screw for the hanger hole For mechanical stability mounting on a rail is recommended 4 3 Ethernet connection The pin assignment of the Etherne...

Page 13: ...ion The configuration of the e cue SYMPL Core S is completely done via e cue SYMPHOLIGHT See the SYMPHOLIGHT System Manual for details on configuration available at www ecue com The network properties of the SYMPL Core S are preconfigured The i Never connect more than one SYMPL Node in factory state to a network The identical IP addresses will conflict and disturb proper communication i The Ethern...

Page 14: ...ties The SYMPL Core S has as factory setting the AutoDHCP enabled Define your login credentials for the web interface of the SYMPL Core S on first access To change the network configuration use either SYMPHOLIGHT or the web interface of the SYMPL Core S 5 2 Network configuration with SYMPHOLIGHT 1 Open the context menu of the SYMPL Core S in the Setup tab of SYMPHOLIGHT by a right click on the dev...

Page 15: ... with the web interface 1 Open a common web browser on a connected PC Enter the SYMPL Core S s IP address into the address bar e g http 192 168 123 1 The remote console of the SYMPL Core S is displayed 2 Select Configuration and the dashboard of the SYMPL Core S is displayed 3 On the left side select Settings and enter the default password ecue ...

Page 16: ...k Submit to apply the settings The network configuration of the SYMPL Core S is completed i The employment of a discrete network is recommended i Note down all employed and if applicable reserved IP addresses Keep the information for future network configurations i You can change the login password to the SYMPL Core S s configuration page and the device name of the SYMPL Core S at Settings page Do...

Page 17: ... If it found one or more USB memory sticks you have a list to select the appropriate USB memory stick You can even plug in the USB memory stick while the Updater runs Set the check marks if you want the contents of the USB memory stick to be verified and if you want the system to remove the USB memory stick after the process After the Updater has finished the process the USB memory stick has a com...

Page 18: ... directly to SD card Follow these steps in order 1 Open file SymplCoreUpdater_ exe 2 Switch to tab Create Image File for SD Card 3 Select a location on your local disk and start the process 4 Download and install Win32 Disk Imager or another image writing tool See link in dialog 5 Open Win32 Disk Imager choose the image file which you created under 4 6 Select the drive letter of the SD card ATTENT...

Page 19: ...f the drive letter corresponds to the SD card If so confirm overwriting 8 When done power off the SYMPL Core S Insert the SD card and power it on Be patient on the first boot it might take longer up to 3 minutes When Master Slave LED of SYMPL Core S lights in blue the device has booted and is operational ...

Page 20: ... 170 g Power supply input 24 V DC on screw terminal wire gauge 0 25 2 5 sqmm 0 5 sqmm for flexible wires with ferrules Power consumption max 12 W incl external USB load Operating temperature 0 40 C 32 104 F Storage temperature 10 70 C 14 158 F Operating storage humidity 0 80 non condensing Protection class IP20 Electrical safety SELV Housing Self extinguishing blend PC ABS UL document E140692 Befo...

Page 21: ...D indicators Master Slave Error Status Ethernet link Power 1 push button System interfaces 1 x e net Ethernet RJ45 CAT5 shielded USB 2 0 Type A microSD card with SYMPHOLIGHT software 9 Certifications e cue SYMPL Core S is certified according to EN 55022 EN 55024 62368 1 Ed 2 4000805 Conforms to ANSI UL Std 60950 1 Certified to CSA Std C22 2 NO 60950 1 ...

Page 22: ...22 Dimensions Abmessungen All dimensions in mm Alle Abmessungen in mm 62 53 5 90 5 ...

Page 23: ...ogies com OSRAM GmbH Sales Operations Karl Schurz Str 38 33100 Paderborn Germany 49 5251 54648 0 support ecue com www ecue com Head office Zentrale Marcel Breuer Strasse 6 80807 Munich Germany Phone 49 89 6213 0 Fax 49 89 6213 2020 www osram com www osram com ecue Light is OSRAM ...

Reviews: