SECTION 7 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS
3121784
7-1
SECTION 7. GENERAL ELECTRICAL INFORMATION & SCHEMATICS
THIS MACHINE IS POWERED BY AN 76VDC (NOMINAL) ELECTRICAL
SYSTEM. BASED ON EMPLOYER, LOCAL, AND GOVERNMENTAL REGU-
LATIONS AS THEY PERTAIN TO THIS MACHINE, SPECIFIC ELECTRICAL
TRAINING AND CERTIFICATIONS MAY BE REQUIRED BEFORE SERVIC-
ING OR TROUBLESHOOTING.
IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELECTRICAL/
ELECTRONIC COMPONENTS. SHOULD PRESSURE-WASHING BE UTI-
LIZED TO WASH AREAS CONTAINING ELECTRICAL/ELECTRONIC COM-
PONENTS, JLG INDUSTRIES, INC. RECO MMENDS A MAXIMUM
PRESSURE OF 750 PSI (52 BAR) AT A MINIMUM DISTANCE OF 12
INCHES (30.5 CM) AWAY FROM THESE COMPONENTS. IF ELECTRICAL/
ELECTRONIC COMPONENTS ARE SPRAYED, SPRAYING MUST NOT BE
DIRECT AND BE FOR BRIEF TIME PERIODS TO AVOID HEAVY SATURA-
TION.
7.1
GENERAL
This section contains schematics to be used for locating
and correcting most of the operating problems which
may develop. If a problem should develop which is not
presented in this section or which is not corrected by
listed corrective actions, technically qualified guidance
should be obtained before proceeding with any mainte-
nance.
7.2
MULTIMETER BASICS
A wide variety of multimeters or Volt Ohm Meters
(VOM) can be used for troubleshooting your equip-
ment. A digital meter with reasonable accuracy (within
7%) is recommended for the measurements in these
procedures. This section shows diagrams of a common,
digital VOM configured for several different circuit mea-
surements. Instructions for your VOM may vary. Please
consult the meter operator’s manual for more informa-
tion.
Grounding
"Grounding the meter" means to take the black lead
(which is connected to the COM (common) or negative
port) and touch it to a good path to the negative side of
the voltage source.
Backprobing
To "backprobe" means to take the measurement by
accessing a connector’s contact on the same side as the
wires, the back of the connector. Readings can be done
while maintaining circuit continuity this way. If the con-
nector is the sealed type, great care must be taken to
avoid damaging the seal around the wire. It is best to
use probes or probe tips specifically designed for this
technique, especially on sealed connectors. Whenever
possible insert probes into the side of the connector
such that the test also checks both terminals of the con-
nection. It is possible to inspect a connection within a
closed connector by backprobing both sides of a con-
nector terminal and measuring resistance. Do this after
giving each wire a gentle pull to ensure the wires are
still attached to the contact and contacts are seated in
the connector.