SECTION 5 - ACCESSORIES
31215918
5-17
SkySense Alarm
Activation of SkySense is also signalled by an audible alarm that
indicates SkySense activity when reaching the warning or stop
zones.
In the warning zone, the audible alarm will pulse and increase in
frequency as the machine moves closer to the object. In the stop
zone, the alarm will sound a continuous tone.
Additionally, when the machine is in the stop zone, the platform
control panel audible alarm will sound, indicating activation of
the SoftTouch system. Reset the system by releasing the trigger
switch.
Audible SkySense alarms can be muted, although LEDs will con
-
tinue to light.
Override Button
The yellow override button allows operators to bypass normal
SkySense operation in order to move closer to an object within
the stop zone.
When the operator overrides SkySense via the override button to
get closer to a work surface, the machine will maintain creep
speed and flash the appropriate indicator color based on location
in either the warning or stop zones.
To
order