SECTION 6 - ACCESSORIES
6-16
31215048
Inspection Before Use
The external fall arrest system must be inspected before each use of
the machine. Replace components if there are any signs of wear or
damage.
Before each use, perform a visual inspection of the following compo
-
nents:
• Cable: Inspect cable for proper tension, broken strands, kinks, or
any signs of corrosion.
• Fittings & Brackets: Ensure all fittings are tight and there are no
signs of fractures. Inspect brackets for any damage.
• Attachment Ring: No cracks or signs of wear are acceptable. Any
signs of corrosion requires replacement.
• Attaching Hardware: Inspect all attaching hardware to ensure
there are no missing components and hardware is properly tight
-
ened.
• Platform Rails: No visible damage is acceptable.
NO GAP: CORRECT
GAP SHOWING:
INCORRECT
GAP SHOWING:
INCORRECT
NO GAP:
CORRECT
Figure 6-1. Bolt-On External Fall Arrest Cable