SECTION 3 - CHASSIS & TURNTABLE
3121827
– JLG Lift –
3-57
To Connect the JLG Control System Analyzer
to the Generator
The JLG Control System Analyzer can be used to monitor
generator settings and conditions. Connect the analyzer
as follows:
1.
Connect the four pin end of the cable supplied with
the analyzer, to the connector behind the ground
control module located on the left side of the
machine next to the ground control station and con-
nect the remaining end of the cable to the ana-
lyzer.The ground control module contains the
settings for the generator.
NOTE:
The cable has a four pin connector at each end of
the cable; the cable cannot be connected back-
wards.
2.
Power up the Analyzer by pulling out the ground sta-
tion EMS and positioning the Generator Enable
switch on the platform control box to the “on” posi-
tion. Refer to Figure 3-23., Generator System Ana-
lyzer Flow Chart
Alarms and Fault Flash Codes
In the event of an RBS alarm, a flash code will be issued
and an alarm indicated on the analyzer.
NOTE:
Alarms must be reset once the fault has been cor-
rected.
• Low Oil Pressure
Enabled once TDBP (time delay bypass) period has
elapsed after engine startup. If the low engine oil pressure
switch closes, the engine will stop immediately and a low
oil pressure alarm will be indicated.
• High Engine Temperature
If the engine oil temperature exceeds the high engine tem-
perature setting, the engine will stop immediately and a
low oil pressure alarm will be indicated.
Table 3-8. Generator System Flash Codes
Code
Alarm
Description
1-1
Low Oil Pressure
Shutdown due to low engine
oil pressure
1-2
High Engine Tem-
perature
Shutdown due to high engine
oil temperature
1-3
Engine Overspeed
Shutdown due to high engine
speed
1-4
E n g i n e U n d e r-
speed/Overcrank
Shutdown due to engine
overcrank or underspeed
1-5
No Speed Signal
Shutdown due to loss of
speed signal
2-1
Overvoltage
Shutdown due to high output
voltage
2-2
E n g i n e S t a r t in g
System fault
Alarm not a shutdown; Indi-
c a t e s p r o b l e m w i t h t h e
engine starting system
2-3
Not Used
Not Used
2-4
L o s s o f Vo l ta g e
Sense
Shutdown due to loss of volt-
age sensing
Contin-
uous
Unit Disabled
No Faults. RBS enabled and
can respond to any CTS
Off
Unit Disabled
RBS off or disabled; Will not
respond to any CTS
Summary of Contents for JLG E400AJP
Page 2: ......
Page 32: ...SECTION 1 SPECIFICATIONS 1 18 JLG Lift 3121827 NOTES...
Page 42: ...SECTION 2 GENERAL 2 10 JLG Lift 3121827 NOTES...
Page 54: ...SECTION 3 CHASSIS TURNTABLE 3 12 JLG Lift 3121827 Figure 3 3 Speed Sensor Orientation...
Page 60: ...SECTION 3 CHASSIS TURNTABLE 3 18 JLG Lift 3121827 Figure 3 7 Steering Components and Spindles...
Page 62: ...SECTION 3 CHASSIS TURNTABLE 3 20 JLG Lift 3121827 Figure 3 9 Tilt Sensor Location...
Page 86: ...SECTION 3 CHASSIS TURNTABLE 3 44 JLG Lift 3121827 Figure 3 16 Swing Components...
Page 88: ...SECTION 3 CHASSIS TURNTABLE 3 46 JLG Lift 3121827 Figure 3 18 Battery Cable Connections...
Page 90: ...SECTION 3 CHASSIS TURNTABLE 3 48 JLG Lift 3121827 Figure 3 20 On Board Generator...
Page 97: ...SECTION 3 CHASSIS TURNTABLE 3121827 JLG Lift 3 55 Figure 3 22 Generator Components...
Page 116: ...SECTION 3 CHASSIS TURNTABLE 3 74 JLG Lift 3121827 NOTES...
Page 127: ...SECTION 4 BOOM PLATFORM 3121827 JLG Lift 4 11 Figure 4 10 Boom Limit Switches...
Page 140: ...SECTION 4 BOOM PLATFORM 4 24 JLG Lift 3121827 Figure 4 13 Rotator Counterbalance Valve...
Page 178: ...SECTION 5 HYDRAULICS 5 24 JLG Lift 3121827 Figure 5 26 HydraForce Cartridge Torque Value Chart...
Page 214: ...SECTION 6 JLG CONTROL SYSTEM 6 34 JLG Lift 3121827 NOTES...
Page 257: ......