SECTION 3 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS
3121801
– JLG Lift –
3-5
3.3 APPLYING SILICONE DIELECTRIC COMPOUND TO AMP CONNECTORS
Silicone Dielectric Compound must be used on the AMP connections for the following reasons:
• To prevent oxidation at the mechanical joint between male and female pins.
• To prevent electrical malfunction caused by low level conductivity between pins when wet.
Use the following procedure to apply Silicone Dielectric Compound to the electrical connectors.
1. To prevent oxidation and low level conductivity, silicone dielectric grease must be packed completely around male and
female pins on the inside of the connector after the mating of the housing to the header. This is easily achieved by
using a syringe to fill the header with silicone dielectric compound, to a point just above the top of the male pins inside
the header. When assembling the housing to the header, it is possible that the housing will become air locked, thus
preventing the housing latch from engaging.
2. Pierce one of the unused wire seals to allow the trapped air inside the housing to escape.
3. Install a hole plug into this and/or any unused wire seal that has silicone dielectric compound escaping from it.
Figure 3-5. AMP Connector
Summary of Contents for JLG 260MRT
Page 1: ...Service Maintenance Manual Model 260MRT 3121801 April 19 2013...
Page 2: ......
Page 8: ...iv JLG Lift 3121801 TABLE OF CONTENTS This page left blank intentionally...
Page 22: ...SECTION 1 SPECIFICATIONS 1 14 JLG Lift 3121801 NOTES...
Page 66: ...SECTION 2 PROCEDURES 2 44 JLG Lift 3121801 NOTES...
Page 91: ...SECTION 3 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3121801 JLG Lift 3 25 NOTES...
Page 95: ...SECTION 3 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3121801 JLG Lift 3 29 NOTES...
Page 104: ...SECTION 3 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3 38 JLG Lift 3121801 NOTES...
Page 105: ......