SECTION 4 - CONTROL COMPONENTS
4-14
31215825
Service Programming Mode - (Level-2)
In the Service Programming Mode the following items are
shown on the main menu:
• Reset Timers• EEPROM Defaults
• Program• OSS Sensor
• Tilt Sensor
Note:
There are two production modules available at this time,
one for North/South American and European languages,
and one for Asian languages. All programmable items
between these modules are identical with the exception of
language selection.
Reset Timers
This setting displays five (5) timers as described following:
•
Trip Time:
This timer displays total accumulated hours since
last trip timer reset. This is the hour meter reading displayed
on the Ground Control Module LCD Display during normal
machine operation.
•
Traction Time:
Displays the amount of accumulated DRIVE
hours on the machine’s current drive components.
•
Lift UP Time:
Displays the amount of accumulated time the
machine has operated the Lift UP function.
•
Lift DOWN Time:
Displays the amount of accumulated time
machine has operated the Lift DOWN function.
•
Total Time:
Displays the total amount of time accumulated
by the Traction, Lift UP and Lift DOWN Timers.
Of these five (5) timers, only the Trip Timer can be RESET back
to zero (00000.0).
•
Brush Wear Sensor Timer:
This timer must be reset after
the drive motor brushes are replaced and the brush wear
sensors are repositioned. When reset the display will go
from WORN to a blank display. Also the 25 hr./10 second
countdown will stop and normal machine operation will
resume.
Program
Allows service personnel to program the Level-2 and Level-3
items shown in Table 4-1.
Tilt Sensor
Allows service personnel to reset the Ground Control Module’s
internal digital Tilt Sensor to zero (0.0) degrees in both the X
and Y axis.
ZEROING THE TILT SENSOR REQUIRES THE MACHINE TO BE
RESTING ON A SURFACE CHECKED WITH A DIGITAL LEVEL
MEASURING WITHIN 0.0 DEGREES LEVEL IN BOTH THE X
AND Y AXIS DIRECTIONS.
Note:
When entering this mode the LCD will display in real time the
current X and Y degree readings of the tilt sensor. The read
-
ing being displayed is based on the previous zero setting and
may not reflect level of the machines current resting surface.
1.
Position the machine on a level surface verified level in
both the X and Y axis with a digital level.
2.
Select “Zero Tilt Sensor” from the menu and press the
Brake Release button.
3.
The current tilt sensor readings are displayed. To zero
both the X and Y direction sensor setting to the
machines’ present resting surface, press the Brake
Release button.
4.
Select “Back to Main Menu” and press the Brake Release
Button.
5.
Power machine off and begin operation.
EEPROM Defaults
Resets programmable settings to factory default settings for
20MVL/MSP models.
Note:
New replacement Ground Control Modules are shipped with
the EEPROM Defaults set up for 15/20/MSP/MVL model
machines. If a the new replacement module is installed on a
10MSP model, the EEPROM Defaults must be reset to the
10MSP model EEPROM Defaults.
Select “EEPROM Defaults” from the menu and press the Brake
Release button. Select the CORRECT machine model, then
push Brake Release button to accept. Power machine off and
begin operation.
OSS Sensor
Displays current Obstruction Sensor System status (Detection -
YES/NO). Also if an object is detected, the sensor(s) detecting
the object and distance the object is from the sensor is dis
-
played.
OSS Sensor LCD Display Mode
1.
Detection Indicator - Yes/No
3.
Object distance from sensor
2.
Sensor numbers
4.
Signal strength
Note:
This screen can be viewed while another person performs
the transducer sensor check, see Section .
00000.0
Go
to
Discount-Equipment.com
to
order
your
parts