SECTION 4 - CONTROL COMPONENTS
4-10
31215825
Cover Removal/Installation
THE MAIN CIRCUIT BOARD AND THE SMALLER LCD CIR
-
CUIT BOARD MOUNTED TO THE COVER ASSEMBLY, COM
-
MUNICATE THROUGH A RIBBON CABLE. REMOVE THE
COVER C AR EFUL LY ON CE THE COVER SC RE WS ARE
REMOVED FROM THE BACK OF THE MODULE.
1.
Remove the (6) Hex Socket Screws from the Heat Sink
/Base. One screw is under the Warranty/Tamper Label.
1.
Ribbon Cable Connector
3.
Support for Cover
2.
Ribbon Cable
1
1
2
3
1.
Ribbon Cable Connector Tabs
(Push tabs away from connector to release
cable then slide cable out of connector)
Note:
Connector works same at both ends of the ribbon cable.
1.
Ribbon Cable Connector Release Tabs
(Slide cable into connector then push tabs
back into connector)
Note:
Connector same at both ends of the ribbon cable.
1
1
1
1
Figure 4-13. Cover Installation
Figure 4-14. Disconnect the Ribbon Cable
Figure 4-15. Release Ribbon Cable
Figure 4-16. Reconnecting Ribbon Cable