SECTION 4 - CONTROL COMPONENTS
31215825
4-9
4.5 GROUND CONTROL MODULE - SERVICE
PROCEDURE
DO NOT ATTEMPT TO DISASSEMBLE THE GROUND CON
-
TROL MODULE IF MACHINE IS STILL UNDER WARRANTY.
OPENING THE GROUND CONTROL MODULE WHILE THE
MACHINE IS UNDER WARRANTY WILL VOID THE WAR
-
RANTY. IF UNDER WARRANTY REQUEST A REPLACEMENT
MODULE FROM THE FACTORY.
The MVL Series and MSP Ground Control Module allows for
field replacement of two (2) components internal to the mod
-
ule.
• Emergency Stop Switch
• Power Selector Switch (Key)
ELECTROSTATIC DISCHARGE CAN DAMAGE COMPONENTS
ON THE IN TEGR ATED C IR C UIT BOAR D. P L AC E THE
GROUND CONTROL MODULE ON A NON-CONDUCTIVE
SURFACE WHEN OPENING.
1.
Cover/LCD Assembly
4.
Emergency Stop Switch
7.
Heat Sink Base/Main Board Assembly
2.
Power Selector Switch Nut
5.
Power Selector Switch
8.
Cover Attach Screws
3.
Emergency Stop Button
6.
Main Board to LCD Ribbon Cable Connector
Figure 4-12. Ground Control Module Components
1
4
5
8
7
2
6