SECTION 6 - TROUBLESHOOTING
31215825
6-27
Code 21 - Beacon - Disconnected
Check For These Obvious Conditions First:
• Is machine equipped with flashing amber beacon light.
Code 22 - Horn - Short Circuit
Check For These Obvious Conditions First:
• Damaged wiring in the horn wiring harness or a damaged horn unit.
Table 6-24. Code 21 - Beacon - Short Disconnected
STEP
ACTION
SPEC
YES
NO
1.
Is machine equipped with a flashing amber beacon light.
—
Go to Step 3
Got to Step 2
2.
At the Ground Control Module enter the programming mode, check
if the Beacon light open circuit detection is enabled.
—
Disable It
Replace Ground
Control Module
3.
Check voltage at the P1 connector on the Ground Control Module
between pin-12 and pin-5. Is reading within specification?
2 - 4 V DC
Replace Ground
Control Module
Go to Step 4
4.
Remove the wire terminals at the beacon, check continuity of each of
the wires from pins-12 and 5 on the P1 connector to the beacon end.
—
Replace the
Beacon
Repair or
Replace Wiring
Table 6-25. Code 22 - Horn - Short Circuit
STEP
ACTION
SPEC
YES
NO
1.
At the Ground Control Module, P1 connector, check the voltage
across pins-14 and 7 to the horn. Is reading within specification?
0 - 2V DC
Go to Step 2
Replace Ground
Control Module
2.
Remove the wire terminals at the horn, check continuity of each of
the wires from pins-14 and 7 on the P1 connector to the horn end.
—
Replace the
Horn
Repair or
Replace Wiring
Go
to