SECTION 6 - TROUBLESHOOTING
6-4
31215825
Continuity Measurement
Current Measurement
Figure 6-3. Continuity Measurement
Figure 6-4. Current Measurement (DC)
• Some meters require a separate button press to enable
audible continuity testing
• Circuit power must be turned OFF before testing conti
-
nuity
• Disconnect component from circuit before testing
• Use firm contact with meter leads
• First test meter and leads by touching leads together.
Meter should produce an audible alarm, indicating conti
-
nuity
• Set up the meter for the expected current range
• Be sure to connect the meter leads to the correct jacks for
the current range you have selected
• If meter is not auto ranging, set it to the correct range
(See multimeter’s operation manual)
• Use firm contact with meter leads