Operating manual external touch control panel (Smart)    Page: 7 of 14 

Overview 

The overview display depends on the devices connected to the touch control panel. 

 

Attraction-Control  

Color-Control.net 

 

 

 

 

 

 

Euromatik.net  

Waterfriend MRD-3  

Silver Steam 

 

 

 

 

 

In the event of faults or alarms in devices, an alarm symbol in the form of a semicircle is displayed 
on the main page to the left of the device measured values. 

Red light indicates an alarm, yellow a warning (e.g. an empty canister at a dosing station). 

 

 

 

 

 

Alarm 

Warning 

Device list 

All connected devices are displayed on this screen. (See the picture on the previous page). 

The  button 

  on  this  page  searches  for  and  queries  all  connected  devices  via  the  osf  bus.  The  survey  is 

carried out automatically every few minutes. 

Each available (linked) device has its own menu structure. 

The button 

 leads to the main menu of the display settings. 

Display settings 

In this menu, settings are made that relate to the external control panel itself and 
not to the devices connected to it. 

About touch display 

This  menu  item  leads  to  a  screen  showing  the  version  and  date  of  the  external 
smart touch control panel program. 

Time & date 

In this menu you can set and synchronize the clocks of all connected devices. To 
synchronize all clocks, you have to press the corresponding button. 

Note:  If  automatic  time  setting  via  the  Internet  is  selected,  all  connected 
devices must be connected to the Internet.

 

Language 

In the Language menu you can change the language for the external touch control panel. 

Screen lock settings 

This submenu contains two settings: 

1.  Screen lock (on or off). When the lock is activated, a key icon is displayed on the bottom line of the 

main screen. Pressing this button will lock all buttons on the screen. To unlock, press the key icon 
again and hold it down for 5 seconds. 

Summary of Contents for TOUCH 310.000.0700

Page 1: ...ontrol EUROMATIK net PC 40 net PC 45 exclusiv Dosing control WATERFRIEND MRD 1 MRD 2 or MRD 3 RGB Lighting controller Color Control NET with 3 Attractions Attraction control for 6 attractions and Attr...

Page 2: ...bout touch display 7 Time date 7 Language 7 Screen lock settings 7 Infoscreen settings 8 Add OSF device LAN connection 8 Service functions 9 Touch screen calibration 9 Factory settings 9 Network setti...

Page 3: ...tabs outwards 2 Make a recess at the intended mounting location in the wall which will later accommodate the tile frame and the housing 3 Align the tile frame in front of the wall recess as follows ho...

Page 4: ...e phase or AC cables in the same cable duct In general laying low voltage cables near three phase or AC cables must be avoided Wiring diagrams The power supply for the touch control panel can either b...

Page 5: ...4 1 Color control net D D D D twisted wire osf Bus 12V supply Euromatik net 12VGND D D 58 61 62 57 Waterfriend MRD 3 2 1 Data Data D D Note the polarity of the bus line more external touch operating...

Page 6: ...local network The easiest way is to connect all network devices to a network switch The range includes the suitable cluster switch plus A standard network cable patch cable CAT5 must be used for conne...

Page 7: ...ructure The button leads to the main menu of the display settings Display settings In this menu settings are made that relate to the external control panel itself and not to the devices connected to i...

Page 8: ...s parameter defines after how many minutes of inactivity the control panel screen automatically switches to the display mode of the info screen If the time has not been set the info screen can be swit...

Page 9: ...factory settings All operational logs remain unchanged Network settings The factory LAN settings of the smart touch device enable plug and play remote control If necessary you can set the IP address m...

Page 10: ...tuation Manual operation In this menu it is possible to switch on the filter pump manually outside of the filter cycles and to start the backwashing manually Pool settings Info display Utility functio...

Page 11: ...and control colored pool lighting and to control three attractions Edit color program The color programs can be edited in this menu after you have previously selected the program for editing Scenes o...

Page 12: ...r Control net can control 10 zones independently of each other In order to implement a complex color composition consisting of several DMX projectors that light up in different colors different projec...

Page 13: ...e screen The minus button removes a device from the list of available devices Here you can set time limits and timers for the 3 attractions It is possible to program 15 independent switching cycles pe...

Page 14: ...Smart Page 14 of 14 Further information can be found on the Internet at the following address https osf de download documents documents php device smart Touch We wish you much joy and relaxation in yo...