OSF 310.000.0580 Installation And Operating Instructions Manual Download Page 1

Installation and Operating Instructions 

 

Filter control unit with built-in level control 

 

and LAN port 

Part no. 

310.000.0580

 

 

Technical data 

Dimensions: 

300mm x 285mm x 85mm 

Operating voltage: 

3/N/PE 400V/230V 50Hz 

Power consumption of control unit: 

 

approx.5VA 

(depends on operating mode) 

Switching 

Pump: 

max. 8A / 3.0 kW (AC3) 

capacity: 

Heater: 

max. 3A / 0.4 kW (AC3) 

 

Dosing system: 

max. 3A / 0.4 kW (AC3) 

 

Auxiliary output: 

max. 3A / 0.4 kW (AC3) 

Degree of protection: 

IP 40 

Level sensors: 

12V Safety Extra Low Voltage (SELV) 

Ambient temperature: 

0-40°C 

Air humidity: 

0-95% non-condensing 

Memory card: 

Micro SD 

Internet port: 

LAN 

Compatible pumps 

230V single-phase pump 
(rated current up to 8A) 

400V three-phase pump 
(rated current up to 8A) 

Speck ECO-Touch-Pro pump 

Speck Badu-90-ECO-VS pump 

Speck Badu-90-ECO-Motion pump 

Pentair IntelliFlo pump 

Pentair SuperFlo pump 

Zodiac FloPro VS pump 

UWE PMM pump 

Summary of Contents for 310.000.0580

Page 1: ...max 3A 0 4 kW AC3 Dosing system max 3A 0 4 kW AC3 Auxiliary output max 3A 0 4 kW AC3 Degree of protection IP 40 Level sensors 12V Safety Extra Low Voltage SELV Ambient temperature 0 40 C Air humidity...

Page 2: ...air IntelliFlo pump 8 Connecting the power supply for a Pentair SuperFlo VS pump 9 Connecting the power supply for a UWE PMM pump 9 Connecting the heating system 9 Auxiliary input 9 Connecting the EUR...

Page 3: ...f 19 Programming the filtration timer 19 Deleting a timer setting 19 Checking the timer settings 20 Setting the ECO filtration times 20 Automatic Continuous running Off 21 Entering editing and deletin...

Page 4: ...ontrol panel 28 Disconnecting the Filter Control plus from the PC 45 exclusiv 28 Operation 2nd filter 29 Home screen 29 Information page 2 filters 29 Service functions 2 filters 30 Alarm settings for...

Page 5: ...ature sensor Terminals for connecting level sensors can be used for convenient automatic control of the water level in the swimming pool There are also terminals for connecting a flow sensor or a pres...

Page 6: ...e relevant regulations observed Always disconnect the unit from the power supply before opening the case All electrical wiring and calibration and servicing work must be performed solely by an approve...

Page 7: ...ump to W1 The factory inserted link between the two terminals 1 and 2 must be removed when connecting a pump fitted with a winding protection switch If the pump does not have a winding protection swit...

Page 8: ...directly to the PC 45 exclusiv unit Connect the speed controller to terminals 10 15 The mains power supply to the pump must be provided separately not via the PC 45 exclusiv There must be a link inser...

Page 9: ...l heating can be connected to terminal U2 This output supplies 230V and is rated for a maximum load of 3A In addition a floating contact is provided at terminals 22 23 e g for controlling the boiler A...

Page 10: ...nsor or a pressure sensor can be connected between terminals 30 and 31 instead of the factory fitted link in order to provide additional protection for the pump against dry running During filtration a...

Page 11: ...ing backwashing then the option Open floor drain during backwashing must be selected in the configuration menu Connecting a pressure switch A pressure switch fitted in the pressure line or in the gaug...

Page 12: ...sor and swimming pool water an R1 2 thermowell part no 320 020 0003 must be fitted in the piping system Solar temperature sensor In addition a solar temperature sensor part no 310 000 0033 can be conn...

Page 13: ...using the probe holder Connect the special cables to a junction box installed by the customer A cable must be laid from this junction box to the control unit e g cable NYM 0 7x1 5 mm 2 The cable must...

Page 14: ...al 52 and touches this probe the level control system automatically switches the filter control unit back on c Automatic actuation operation with 5 probes If water displacement in the swimming pool ha...

Page 15: ...ten the sliding bracket in place All the parts fit easily inside each other so no great force is needed Level measurement in the standpipe The level can also be measured with the help of 2 immersion e...

Page 16: ...d To switch on the unit touch any point on the screen for at least 3 seconds Heating Network connection Home Menu Info button Home Menu Info button Back Cancel without saving Home Menu Information but...

Page 17: ...ns the filtration pump at a lower speed allows the spillway to run dry or reduces the water temperature Party mode runs continuously Switches on the filtration system even though the timer has switche...

Page 18: ...he Heating settings button Setting the water temperature Use the screen keypad to set the water temperature you require Then press the OK button to save the temperature Temperature reduction in Eco mo...

Page 19: ...OFF Note the icon on the right ON runs continuously AUTO runs under timer OFF switched off Programming the filtration timer Tap the Filtration timer button Tap the Add new time button Tap the relevan...

Page 20: ...elect the time you want Tap X to delete the timer setting This cannot be undone Checking the timer settings Tap the Filtration timer button The table shows the programmed switching times for the timer...

Page 21: ...ON runs continuously AUTO runs under timer OFF switched off Entering editing and deleting ECO timer settings The ECO timer can be programmed in the same way as the Filtration timer described above Bac...

Page 22: ...a rate of twice weekly or three times or four times a week You can program additional backwash times here The length of time that backwashing lasts is programmed in the Service settings Setting up Par...

Page 23: ...cators The Reset button can be used to clear fault indicators e g after the electronic motor protection device has actuated Tap the Information button Log This screen shows the event log The PC 45 exc...

Page 24: ...ttings button to open the Service settings for pool components menu Set the level control parameters Tap the Skimmer button to switch to the settings level Here you can set the delay switching interva...

Page 25: ...nt overfilling in case the water level sensor develops a fault Time limit for refilling This is where you can set the time limit for the time monitoring option Refilling while washing In this line you...

Page 26: ...required in order to implement the frost protection function The temperature reading is displayed in the main screen The temperature measured by the Air temperature sensor for indoors is displayed in...

Page 27: ...rconnections Connect one end of the patch cable to the LAN port of the control unit and the other end to the network switch or LAN outlet socket of the local area network Once you have connected the c...

Page 28: ...o control units This pushbutton is located in the wiring compartment on the circuit board on the right between the connecting terminals When you press the LAN button briefly the indicator light on the...

Page 29: ...exclusiv also shows the status bar for the second filter Heating status Status of filter number 2 Filter Control plus Status of filter number 1 PC 45 exclusiv Backwashing of 2nd filter using slide val...

Page 30: ...are configured in the same way as for the first filtration system You can find further details in the Pro mode section of the instructions for the PC 45 exclusiv filter control unit Configuring two f...

Page 31: ...in which one filter is backwashed by both pumps simultaneously Characteristics When backwashing takes place the connecting valve opens and the shut off valve for the other filter closes One pump for t...

Page 32: ...information designed to suit the needs of different user groups Mypool osf de This server is designed for pool owners The entire pool system including all web enabled osf products is displayed on one...

Page 33: ...tion link in the e mail to activate your account Registering a new device with the server Once you have personally registered you can log in and then register your new device in your user profile Each...

Page 34: ...es button your device is now displayed in your Device panel and can be operated via the communication server In order to use the communication server the option Internet connection via communication s...

Page 35: ...tion link in the e mail to activate your account Registering a new control unit with the server Once you have personally registered you can log in and then register your new device in your user profil...

Page 36: ...highlighted for each pool individually To display and operate a specific device via the communication server simply press the associated button for this device In order to use the communication serve...

Page 37: ...ivation link in the e mail to activate your account Registering a new device with the server Once you have personally registered you can log in and then register your new device in your user profile E...

Page 38: ...munication server must be enabled in the control unit itself default factory setting Changing the PIN password The PC 45 exclusiv contains 2 level password protection for access via the LAN The User P...

Page 39: ...y pressing the button 7 You can now assign new values to each PIN Make sure you make a note of the PINs Naming the unit Entering an e mail address In order to be able to identify different control uni...

Page 40: ...ating to work You can perform the update via the WEB interface of the communication server Checking for updates You can use this function to check whether an update is available for your device 1 Log...

Page 41: ...valid HTML file but can be formatted to suit the requirements of the building automation system This control file can contain variables in the format nnnn which the web server then replaces with the d...

Page 42: ...pen 0 closed 0 modest 1 pump1st 0 pump2st 1 pump3st 1 language de acwday Donnerstag actime 11 52 acdate 22 Apr 2021 isodat 2021 04 22T11 52 46 01 Description device name serial number Firmware version...

Page 43: ...i Start Stop 0027 Backwash filter 2 W ASCII i Start Stop 0028 Backwash filter 3 W ASCII i Start Stop 0100 Water temperature R 0101 Solar temperature R 0102 Air temperatuer R 0110 Setpoint water tempe...

Page 44: ...swimming pool Further information can be found on the Internet at the following address https osf de download documents documents php device PC 45 exclusiv Hansj rgen Meier Elektrotechnik und Elektro...