oserio FTG-588 User Manual Download Page 1

User Manual

FTG-588 Body Composition & Cardio Scale

Please keep the instruction manual at hand all the time 
for future reference.

Summary of Contents for FTG-588

Page 1: ...User Manual FTG 588 Body Composition Cardio Scale Please keep the instruction manual at hand all the time for future reference...

Page 2: ...ion of manufacturer of medical product including address Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C Electro medical appliance with attachment for type BF Dis...

Page 3: ...y a failure to adhere to requirements stated in this manual Charder reserves the right to correct misprints in the manual without prior notice and modify the exterior of the product for quality purpos...

Page 4: ...Explained 3 4 About Bioelectrical Impedance Measurement 9 9 11 14 Caring for your product 4 1 Use Storage 4 2 Service and maintenance 16 16 Troubleshooting 5 1 Error Messages 17 Product Speci cations...

Page 5: ...is intended to measure the weight and bioelectrical impedance of children or adults who can stand unassisted using input data to calculate subject s body composition General Handling Product should b...

Page 6: ...r household waste but should be taken to a designated collection points for electronics Further information should be provided by local waste disposal authorities Usage of Results The FTG 588 is not a...

Page 7: ...S or Android device with operational Bluetooth and Wi Fi is required to download the o Care app and retrieve measurement results from the product After installation product and app is ready for use Cr...

Page 8: ...7 Product Description 2 1 Overview LED screen Measurement platform Feet Battery cover...

Page 9: ...ect orientation If batteries are inserted incorrectly product will not function If product will not be used for a long period of time 3 months remove the batteries before storage Insert 3 AAA batterie...

Page 10: ...ct turns o automatically after a short period of time self calibration is complete Weight measurement in process Remove shoes and socks and ensure soles of feet are clean Stand on product for measurem...

Page 11: ...measurement to allow product to automatically pair and sync After result transfer is complete product will automatically shut down 1 If o care app is not open on smartphone results will not be transfe...

Page 12: ...d is positively correlated with increase in muscle Basal Metabolic Rate BMR BMI is a commonly used index by the World Health Organization WHO utilizing height and weight to classify underweight normal...

Page 13: ...Moore FD Haley HB Bering EA Brooks L Edelman I Further observations on total body water Changes of body composition in disease 1952 Surg Gynecol Obstet 95 p 155 180 2 3 4 5 Body water refers to the w...

Page 14: ...body composition readings It works on a percentage basis with 100 being the highest possible score attainable Health Score The product uses patented heart rate measurement technology to measure your...

Page 15: ...h reference to gold standard measurements such as Dual Energy X ray Absorptiometry DXA to con rm viability and accuracy 1 Do not exercise or perform strenuous physical tasks before measurement Strenuo...

Page 16: ...re conditions 24 28 C Extreme temperatures both hot and cold can result in temporary physiological changes For example excessive sweating due to heat can cause increased impedance measurements resulti...

Page 17: ...ation when not in use away from direct sunlight and extreme temperatures 2 This product is not a toy Children should not be allowed to play with it 3 Avoid corrosive liquids and materials Do not use d...

Page 18: ...capacity Stay still and avoid movement during measurement Data transfer error Data sent from smartphone to product resulted in error Try measurement again Data transfer error Data sent from product to...

Page 19: ...l Muscle Percentage Protein Health Score Heart Rate Model Battery Product Weight FTG 588 Body Composition Cardio Scale 3 AAA batteries 1 6kg Dimensions Product 290 W x 300 D x 25 H mm Screen 66 W x 32...

Page 20: ...ly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Class B RF emissions CISPR 11 Class A Harmonic emissions IEC 61000 3 2 Compliance Voltage...

Page 21: ...line s to earth 1kV line s to line s 2kV line s to earth Mains power quality should be that of a typical commercial or hospital environment If the user of the product requires continued operation duri...

Page 22: ...Portable and mobile RF communications equipment should be used no closer to any part of the product including cables than the recommended separation distance calculated from the equation applicable to...

Page 23: ...the frequency of the transmitter where p is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE1 At 80 MHz and 800 MHz the separation distance...

Page 24: ...Manufactured by Krell Precision Yangzhou Co Ltd No 28 Xinyang Rd Development Zone Yangzhou City Jiangsu Province 225009 P R China on behalf of Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Ta...

Reviews: