OSBURN HYBRID-45 MF FREESTANDING PELLET STOVE
Width: 27”
Height: 30 1/2”
Depth: 24 5”
Weight: 230 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 60 lbs.
(This can vary widely depending on pellet size, length, and diameter)
EPA status: exempt
Burn rate: 1.3 lbs to 5.5 lbs. per hour
BTU range: 8,200 to 45,000
Electrical consumption: 3.5 Amps lighting cycle
2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
Igniter: 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional
PREPARATION
Factory packaging must be removed, and some minor assembly work is
required prior to installation:
The door overlay must be installed on the door frame;
The louver kit must be installed in front of the heat exchanger;
The black knob must be attached to heat exchanger rod;
Filters may be inserted between finger guard and convection
blower (see “filters installation” section).
NOTE: Normally, your dealer will perform these functions.
CLEARANCES
The Osburn Hybrid-45 MF has been tested and listed for installation in
residential, mobile home.(refer figure 1 to 3)
In the USA, the unit must be installed on a non-combustible floor pad
extending at least 6 inches (155 mm) in front of the door opening and at least
6 inches (155 mm) on each side of the door opening. In Canada, the unit
must be installed on a noncombustible floor pad extending at least 18 inches
(460 mm) in front of the door opening and at least 8 inches (205 mm) at the
back and on each side of the unit. The floor pad must have a thickness of at
least 0.015'' (0.38mm). NOTE: ceramic tile, or any tile, must be laid on a
continuous non combustible sheet to prevent the possibility of embers falling
through to the combustible floor if cracks or separation should occur in the
finished surface.
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER
We recommend leaving 24’’ on each sides of the appliance in order to facilitate access for maintenance.
CLEARANCES TO COMBUSTIBLES
CANADA USA
A
2’’ (55 mm)
2’’ (55 mm)
B
6’’ (155 mm)
6’’ (155 mm)
C
2’’ (55 mm)
2’’ (55 mm)
D
3’’ (80 mm)
3’’ (80 mm)
FLOOR PROTECTION
CANADA USA
E
18’’ (460 mm)
6’’ (155 mm)
F
N/A (USA only)
6’’ (155 mm)
G
8’’ (205 mm)
N/A (Canada only)
H
8’’ (205 mm)
N/A (Canada only)
Door
opening
FIGURE 2
Corner installation
FIGURE 1
Back wall installation
FIGURE 3
Floor protection
INSTALLATION
5