Osburn HYBRID-45 MF Owner'S Manual Download Page 27

 
 

ALARM CODES CHART  

MESSAGE CORRESPONDING 

WARNING 

 

Pressure switch warning. 

 

Warning caused by one of the two automatic L-250 sensors: one is located under the pellet chute and the other 
one is inside the hopper heat shield. 

 

L-250 manual reset high temperature switch, located beside convection blower. 

 

Hopper is empty 

 

Lighting warning. 

 

Hopper lid stay open more than 3 minutes. 

 

Inverted polarity in power outlet. 

 

Power outage  

 

Igniter fuse is burnt out. 

 

SMOKE SMELL OR SOOT BUILD-UP 

Because it is a wood-burning device, your Osburn  Hybrid-45 MF may emit a faint wood-burning odor. If this increases beyond normal, or if 
you notice an unusual soot build-up on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed. 
Also clean your stove, following instructions in “

MAINTENANCE

”. If problem persists, contact your dealer. 

 
 
 

TROUBLESHOOTING GUIDE 

27

Summary of Contents for HYBRID-45 MF

Page 1: ...instructions Some surfaces become hot at higher feeding rates To prevent potential burns avoid contact with those areas This heating unit must serve as a supplementary heat source An alternative heat...

Page 2: ...a freestanding room heater It is also approved as a mobile home heater which is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a...

Page 3: ...ise to operational levels one of the sensors could then make the stove start on its own It is recommended that the stove be unplugged when not in use for extended amounts of time i e during the summer...

Page 4: ...lation 16 Please Read This Operating Safety Precautions 18 MAINTENANCE 19 Ash Removal 19 Ash Disposal 19 Vacuum Use 20 Cleaning 20 Blowers 20 Chimney Cleaning 21 Recommended Maintenance Schedule 21 Re...

Page 5: ...n the USA the unit must be installed on a non combustible floor pad extending at least 6 inches 155 mm in front of the door opening and at least 6 inches 155 mm on each side of the door opening In Can...

Page 6: ...nt that meets the ULC S 609 M89 and ULC ORD C441 M90 Standards For the United States we recommend that you use a listed pellet vent that meets the UL 641 7 th edition Standard This unit can be vented...

Page 7: ...h enough piping to penetrate and extend at least 6 inches beyond the exterior wall There should always be at least one foot of vertical rise for each foot of horizontal run see Appendix A At least 3 f...

Page 8: ...above paved side walk or a paved driveway located on public property 39 100 cm Clearance to property boundary A vent shall not terminate underneath a veranda porch or deck United States Not Less than...

Page 9: ...in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof along upper edge Do not nail lower edge Seal nail heads with flexible...

Page 10: ...the center of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to break out the masonry around the location of the pipe center mark Use a 4 inch diameter hole for 3 inch...

Page 11: ...that came with your owner s manual Fix the two brackets using the same screws you have removed Lay the log set inside the firebox as shown on figure 14d 14e SCREWS SCREWS LOG SUPPORT LOG SUPPORT LOG...

Page 12: ...lar basis as per our recommended maintenance schedule This is particularly critical if you have animals in your house such as a dog or a cat Filters that are not cleaned can clog up and cause your sto...

Page 13: ...ash content should be indicated on the bag by the pellet manufacturer PRE START UP CHECK Remove burn pot making sure it is clean and none of the air holes are plugged Clean the firebox and then reins...

Page 14: ...e fuel feed rate When the NOISE REDUCER button is pushed the convection blower will switch to its lowest speed The convection blower will remain at its lowest speed unless the stove reaches a certain...

Page 15: ...EDURE Turning your Osburn stove off is a matter of pressing the MODE control panel switch until the OFF led goes on The blowers will continue to operate until internal firebox temperatures have fallen...

Page 16: ...fort and efficiency from you Hybrid 45 MF The thermostat should be mounted 50 inch from the floor on a wall located 15 to 20 feet from the stove You should avoid an installation directly in front of t...

Page 17: ...ard to let you know that you are in the PILOT ON mode If you wish to go back to the default thermostatic mode i e the unit shuts down after 45 minutes if the thermostat does not call for heat simply p...

Page 18: ...ambient air in a confined room becomes to hot the stove may overheat and the thermal protection on the combustion exhaust motor may be activated causing the motor to stop d KEEP ALL LOOSE OR MOVEABLE...

Page 19: ...ure 18 19 d Open the door and remove the burn pot by grasping it and pulling straight out Scrape the burn pot with a scraper if necessary Make sure that the burn pot holes are not plugged Empty ashes...

Page 20: ...AT THIS OPERATION AT LEAST ONCE PER TON OF PELLETS BURNED UNTIL YOU ARE FAMILIAR WITH HOW ASHES ACCUMULATE WITH YOUR OPERATING PRACTICES BLOWERS DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE S...

Page 21: ...fied chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney...

Page 22: ...alled Check to make sure vent pipe installation meets the criteria in the owner s manual as well as the pipe manufacturer s recommendations 4 The airflow pressure switch wire connections are faulty Ch...

Page 23: ...ft from the auger housing Start by emptying the hopper Take the rear panel off the stove body Then take the auger motor off by removing the screws that hold the motor to the auger shaft Once the motor...

Page 24: ...d the unit will stop after the ignition cycle If this situation occurs call your dealer or technician 5 The control board is not sending power to the igniter Check the voltage going to the igniter dur...

Page 25: ...ain SMOKE SMELL COMING BACK INTO THE HOME Possible Causes Possible Remedies 1 There is a leak in the vent pipe system Inspect all vent pipe connections This is a pressurized exhaust system All vent co...

Page 26: ...ately 3000 RPM You will need a technician to perform this test 7 Bad pellets Applies to GLASS SOOTS UP AT A VERY FAST RATE Only The brand of pellets or the batch of pellets that are being used may be...

Page 27: ...id stay open more than 3 minutes Inverted polarity in power outlet Power outage Igniter fuse is burnt out SMOKE SMELL OR SOOT BUILD UP Because it is a wood burning device your Osburn Hybrid 45 MF may...

Page 28: ...TION BLOWER SWITCH L 250 HIGH TEMPERATURE MANUAL RESET HIGH TEMPERATURE SWITCH F 160 SWITCH L 250 AUTOMATIC HIGH TEMPERATURE CONTROL AIR SUPPLY INTAKE FRESH AIR COMBUSTION EXHAUST BLOWER MOTOR CLEANIN...

Page 29: ...ide SE52710 Exhaust Adapter 3 SE52572 Hot Rod Igniter 44030 Thermistor 44095 F 160 Convection blower heat sensor 44058 L 250 Automatic High Temp Switch 44059 L 250 Manual Reset High Temp Switch 44041...

Page 30: ...al vent coming out at the back of the stove on a total distance of 4 feet followed by a Tee and a 6 foot vertical rise it would be acceptable The installation would end be within the allowable configu...

Page 31: ...valent vent lenght calculation table DRAW YOUR INSTALLATION 1 SQUARE 1 F00T PART DAILY 10 bags 25 bags E xchanger Baffle Left interior channel Hopper Evacuation blower Blower blades Pressure system Bu...

Page 32: ...osts covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the def...

Reviews: