35
3.3.9 B-vent adapter installation
This unit may be modified for use as a vented room heater, by using the optional B-Vent adapter. The
following instructions are to be used when using this option.
1. Remove the B-Vent Adapter Assembly and the Outer Collar from the box.
2. Carefully slide the Outer Collar up from the bottom of the B-Vent Draft Diverter (Adapter)
Assembly (inside flange up), ensuring that the two wires are inside the collar passing through
the flange notch, to avoid scratching the visible surface.
3. Place the adapter on top of the flue outlet, ensuring that the 6" diameter B-Vent Draft Diverter
(Adapter) is as far down as it will go (it will rest on the bottom of the air inlet portion of the
stove).
4. Run three Teck screws through the outside of the 6 5/8" diameter inlet collar of the stove, and
into the 6" diameter of the adapter, at convenient locations equally spaced.
5. Slide the Outer Collar down to the surface of the unit with the seam to the rear.
NOTE:Failure to do any of the below three items violates the use of the B-Vent Draft Diverter
(Adapter).
6. Remove the jumper plug attached to the valve assembly and discard.
7. Attach the spill switch plug to the valve.
8. Remove the cover plate from the bottom of the firebox floor, 8 hex head screws.
9. Install Listed B-Vent pipe.
10. The drafthood shall be installed in the same atmospheric pressure zone as the combustion air
inlet to the appliance and shall be located so that the relief opening is accessible for checking
vent operation.
NOTE: In B-vent installation use a 40% restrictor for any vertical length.