Supplemental Information 

 

SCA 1200ht Support Cleaning Apparatus Limited Warranty 

Product 

Limited Warranty Period 

SCA 1200ht Support Cleaning Apparatus 

1 year 

All  new  Support  Cleaning  Apparatus  (SCA)  systems  are  warranted  exclusively  by 
Oryx Additive

, Inc.’s (“Manufacturer”) limited warranty as follows: 

Each  Support  Cleaning  Apparatus  system  (“System”)  and  its  components 
(“Components”), except those listed below under limits and exclusions, is warranted 
against  defects  in  the materials  and  workmanship  for  a  period  of  one (1)  year from 
the date of installation at the end user

’s (“Customer”) facility. 

Repair  or  replacement  only:  manufacturer's  liability  under  this  agreement  shall  be 
limited  to  repairing  or  replacing,  at  the  discretion  of  manufacturer,  parts,  or 
components sufficient to return the system to conform to the marketing specifications 
of the system.  

Components subject to wear during normal use and over time such as paint, finish, 
light bulbs, seals, etc., are excluded from this warranty. 

This  warranty  is  void  if  the  system  is  subjected  to  mishandling,  misuse,  neglect, 
accident,  improper  installation,  improper  maintenance,  or  improper  operation  or 
application,  or  if  the machine  was  improperly  repaired  or  serviced  by the  customer.  
This  warranty  is  void  if  the  system  is  not  installed  by  a  certified  distributor  and  the 
proper  installation  documentation  provided  by  the  manufacturer  has  not  been 
submitted. 

Liability, whether based on warranty, negligence or other cause, arising out of and/or 
incidental to sale, use or operation of the system, or any part thereof, shall not in any 
case exceed the cost of repair or replacement of the defective equipment, and such 
repair or replacement shall be the exclusive remedy of the purchaser, and in no case 
will  manufacturer  be  responsible  for  any  and/or  all  consequential  or  incidental 
damages including without limitation, and/or all consequential damages arising out of 
commercial losses. 

This  warranty  is  transferrable  from  the  original  end  user  to  another  party  if  the 
machine is sold via private sale before the end of the warranty period. 

The  foregoing  is  a  limited  warranty  and  it  is  the  only  warranty  by  manufacturer. 
MANUFACTURER  DISCLAIMS  ALL  OTHER  WARRANTIES,  EXPRESS  OR 
IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO  ALL  WARRANTIES  OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

Summary of Contents for SCA 1200ht

Page 1: ......

Page 2: ...2 This page intentionally left blank...

Page 3: ...sposal 10 Operation 11 Filling and setup 11 Preheating and starting the cleaning cycle 12 Completing the cleaning process 15 Maintenance 16 Draining the tank 16 Disposing of solution 16 Cleaning the S...

Page 4: ...require the unit to be plugged into a Ground Fault Interrupt GFI or similar protected outlet Always power off and unplug the SCA from the power outlet when it is being cleaned moved or serviced Do no...

Page 5: ...out autre fin que de retirer les mat riaux de support solubles de pi ces 3D imprim es Portez des gants thermiques et des lunettes de s curit lorsque vous travaillez avec ou proximit du SCA Reportez vo...

Page 6: ...is completely removed models are unloaded from the SCA rinsed dried and ready for further finishing or use Package contents The SCA is shipped with the following contents SCA System 1 Large Part Bask...

Page 7: ...e liquid in the tank The Large Parts Basket is used to hold parts during cleaning and to lift parts out of the tank Users should wear thermal gloves when lifting the basket from the tank The Small Par...

Page 8: ...ply unscrew the nozzle and rinse with tap water to un clog holes The Pump Intake Screen prevents large particulates from entering the pump It may occasionally need to be cleaned with a soft brush or t...

Page 9: ...lity The tank is drained by connecting a hose to the Drain Tube and turning the Drain Valve to the open position The liquid in the tank should be at room temperature and the unit should be turned off...

Page 10: ...should be easily accessible at all times Position the unit so that the plug can be easily reached It is strongly recommended that the unit be placed on a circuit with its own GFCI breaker Place the un...

Page 11: ...ank unless the liquid level is above the MIN line as shown N UTILISEZ PAS d eau chaude lors du remplissage du r servoir L ajout de concentr s de nettoyage l eau est une r action de d gagement de chale...

Page 12: ...s SDS for PPE and handling requirements If using EcoWorks 1 Open the foil cleaning agent packet as shown Each packet contains an A B pouch 2 Empty all the contents of 6 6 foil cleaning agent packets...

Page 13: ...to the cleaning solution press the button to pause the heater and pump With the basket cutout facing the nozzle slowly lower the large parts basket into the solution filled tank The flow nozzle should...

Page 14: ...opening the lid carefully lifting the Large Parts Basket from the tank turning the basket 90 and resting it on the rear support bracket and then pulling it forward on to the front tank ledge Protecti...

Page 15: ...des pi ces mouill es avant qu elles n aient t rinc es Let the basket rest above the tank while draining After draining remove the parts from the basket and rinse them with water to remove any residua...

Page 16: ...fluents Power off the unit and unplug from the wall receptacle Ensure the drain strainer is in place at the bottom of the tank Attach a 1 inch 25 4 mm inner diameter hose or tubing to the end of the d...

Page 17: ...erior surfaces of the SCA and the inside of the tank Never immerse the system Any liquid in the electronics area of the system may cause damage or system failure and void the warranty Contact the manu...

Page 18: ...face Scrub debris from the intake screen using a stiff brush Rinse with water Verify all holes are unplugged before replacing the screen on the pump intake Moving the SCA Always use two people to lift...

Page 19: ...Large basket Small parts basket Pump subassembly w nozzle Heater subassembly Sensor subassembly Display Control Panel PCB subassembly Power switch Spray nozzle Figure 11 SCA 1200ht Assembly List of Re...

Page 20: ...ET DES YEUX Problem Probable Causes What to Do Power Indicator is not Lit after pressing the button Power switch is not On Press rocker switch on the right side of the unit to the On position Power co...

Page 21: ...l If the Alert light is on open the lids and lift the part basket from the tank Let the liquid cool and try starting the cycle again If it overheats a second time contact technical support Over temper...

Page 22: ...t Pump intake screen is clogged Drain the tank as instructed in the Maintenance section Clean the intake screen with a stiff brush until debris is removed from the holes Flow from nozzle is not unifor...

Page 23: ...Works is a more efficient cleaning concentrate Liquid Level indicators did not turn off when liquid was added removed from the tank Sensors or Indicators have failed Contact technical support System i...

Page 24: ...es 10 x 10 x 10 cm Operating Environment Ranges Temperature 5 C 40 C Humidity 0 80 RH Altitude 0 M 2000 M Temperature Control Accuracy 2 C Pump Max Flow Rate 10 GPM 38 LPM Temperature Display Digital...

Page 25: ...unit was purchased Otherwise to receive technical support www oryxadditive com support proceed to the Request Technical Support page and fill out the support request form send an e mail to support or...

Page 26: ...ct accident improper installation improper maintenance or improper operation or application or if the machine was improperly repaired or serviced by the customer This warranty is void if the system is...

Reviews: