3
ORTNER GmbH | Hürmer Straße 36 in A-3382 Loosdorf | Tel +43 2754 2707 | Fax +43 2754 2708
[email protected] | www.ortner-cc.at
The following materials are required for the assembly of the Ortner storage corner
Fibre mat strips (for sealing between the ceramic and the metal parts), included in the delivery
Bedding mortar HK for the bonding of the combustion chamber jacket, included in the delivery
Open-end spanner 30 mm or pipe wrench for the height adjustment of the base frame
Allen keys
–
set
Size 10 socket or open-end spanner
Technical specifications
When used with the KMS:
Type designation
SE11 56/56/42
Heat output in regard to the storage duration of 12 h (with ceramic flue gas tubes; KMS
300 or chamotte flue)
2,9 kW
Rated heat output in relation to the combustion duration
52 kW
Max. wood amount
11 kg
Total mass (without ceramic hot gas flues)
ca. 460 kg
Degree of efficiency
>80 %
Stack gas mass flow
52 g/s
Minimum distance to adjacent combustible substances (when installed freestanding)
front
100 cm
side
20 cm
rear
20 cm
Pipe connection temperature (upstream of the ceramic post-heating surface)
517 °C
Mean exhaust temperature (downstream of the ceramic storage unit KMS 300)
125 °C
Mean required discharge pressure with rated heat output
14 Pa
When used with the KAM (only permissible in partial-load operation):
Type designation
SE11 56/56/42
Heat output with 12 h storage duration with KAM
2,1 kW
Rated heat output in relation to the combustion duration
38 kW
Max. wood amount
8 kg
Total mass (without ceramic hot gas flues)
ca. 460 kg
Degree of efficiency
>80 %
Stack gas mass flow
49 g/s
Minimum distance to adjacent combustible substances (when installed freestanding)
front
100 cm
side
20 cm
rear
20 cm
Pipe connection temperature (upstream of the ceramic post-heating surface)
517 °C
Mean exhaust temperature (downstream of the ceramic storage unit KMS 300)
215 °C
Mean required discharge pressure with rated heat output
20 Pa