1.
To access the
NTP Status Summary
panel, navigate to
MANAGEMENT >
NETWORK: NTP Setup
.
2.
The
NTP Status Summary
panel is at the lower left of the screen. The panel con-
tains the following information:
Selected Ref
—The reference VelaSync is currently using.
Stratum
—This is the stratum level at which VelaSync is operating.
Leap Indicator
—The leap indicator bits (usually 00). See
Alert Notification" on page 105
.
Delay (ms)
—The measured one-way delay between VelaSync and its selec-
ted reference.
Offset (ms)
—Displays the configured 1PPS offset values.
Jitter (ms)
—Variance (in milliseconds) occurring in the reference input time
(from one poll to the next).
4.7.1.4
Monitoring the Oscillator
The Oscillator Management screen provides current and history status information on dis-
ciplining state and accuracy.
To access the
Oscillator Management
screen:
192
CHAPTER
4
•
VelaSync 1232 User Manual Rev. 4
4.7 Quality Management
Summary of Contents for Spectracom VelaSync 1232
Page 2: ......
Page 4: ...Blank page II VelaSync 1232 User Manual...
Page 12: ...BLANK PAGE X VelaSync 1232 User Manual TABLE OF CONTENTS...
Page 28: ...16 CHAPTER 1 VelaSync 1232 User Manual Rev 4 1 7 The VelaSync Web UI...
Page 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync 1232 User Manual Rev 4...