-158,"String data not allowed"
. String data detected when number is expected.
-160,"Block data error”
. This error, as well as errors –161 through –169, is gen-
erated when parsing a block data element. This particular error message is used
when the instrument cannot detect a more specific error.
-161,"Invalid block data"
. A block data element was expected, but was invalid for
some reason (see IEEE-488.2, 7.7.6.2); for example, an END message was received
before the length was satisfied.
-190,"Execution in progress"
. Command not allowed in current state.
-191,"Execution not in progress"
. Command requiring scenario/signal generator
executing issued when device is idle.
-192,"Unused channel"
. Query or command for a channel that is currently not alloc-
ated to any signal.
-193,"RSG command overflow occurred"
. Too many RSG commands were
received to process within a GSG 10 Hz epoch.
-194,"RSG command underflow occurred"
. Underflow detection was enabled,
and no GSG RSG commands were received within a GSG 100 ms epoch.
-200,"Execution error"
. Scenario execution failed to start.
-220,"Parameter error"
. Scenario/signal generator started without a scenario.
-221,"Settings conflict"
. Indicates that a legal program data element was parsed
but could not be executed due to the current counter state (see IEEE-488.2,
6.4.5.3 and 11.5.1.1.5.)
-221,"Settings conflict; invalid combination of channel and function"
. See
above.
-222,"Data out of range"
. Indicates data values are out of range or input data such
as Navigation data files have incompatible ranges of validity.
-224,"Illegal parameter value"
. Scenario configuration has illegal coordinates or
date.
-225,"Out of memory"
. Command processing was interrupted because of the lack
of memory.
-241,"Hardware missing"
. This error is given only when the reference clock signal
is missing when scenario/signal generator is started or when the Ethernet MAC
address cannot be found. Check that the external reference clock is connected.
Verify Network Ethernet Port detection and activity lights.
-250,"Mass storage error"
. Copying/moving files is not allowed between dir-
ectories.
-256,"File name not found"
. File operation attempted on a non-existing file or dir-
ectory.
226
User Manual GSG-5/6 Series Rev. 27
6.2 Protocol