background image

 

4

  5

1. Drill 2 holes in the wall and place mounting screws in them.
2. Connect the cables to the connection sockets on the back 
of the uniphone according to the connection diagram.
3. Fix the back of the uniphone to the wall mounted screws.
4. Hang up the handset on the base.
5. Connect the power supply to 230VAC, 50Hz.

The  correct  location  of  the  external  panel  ensures  comfortable  device  operation.  It  is  recommended  to 
experimentally choose the best possible location for the device prior to drilling the mounting holes.

 To do this, do not 

place the external panel and the uniphone in the same room, as feedback may form.
The external panel is suitable for surface mounting.

3.1. Installation of external panel

3.2. Installation of the uniphone (indoor unit)

The set does not include an electric strike and automatic gate control unit!

fig. 3 Installation of the external panel

fig. 4

1. Drill two holes in the wall/post where the external panel is to be mounted.
2. Place the mounting screws in the prepared holes.
3. Put the protective cover in the place of installation.
4. Tighten the mounting screws.
5. Put the outer cassette on.

Surface mounting   

wall  

wall  

4. WIRING DIAGRAM

4.1. Connection diagram of electric striker

fig. 5 Wiring diagram

5. SET EXTENSION

5.1. Wiring diagram of two uni phones

While designing the wiring system, take into account the suitable cross-section of cables:

2

u

p to 30 m – recommended cable XzTKMXpw 

3 x 

2 x 0,5 mm

2

from 30 m do 100 m – recommended cable XzTKMXpw 

3 x 

2 x 0,8 mm

2

The connection to the electromagnetic lock should be made with 2 x 1 mm .

Any 12 VDC electric striker with a max current draw of 500 mA can be connected to the set.

The total length of the installation must not exceed 100 meters.
The use of twisted-pair cables is absolutely not recommended.

The set does not include an electric strike and automatic gate control unit and uniphone!

fig. 6 Wiring diagram

3. INSTALLATION

Do not make any connections if the device is connected to a 230 V network! 

Failure to follow these instructions may result in damage to the appliance!

External panel

Unifone 1

Unifone 2

electric

gate

control

stricke

Summary of Contents for OR-DOM-AT-930/W

Page 1: ...ORNO LOGISTIC Sp z o o ul Rolnik w 437 44 141 Gliwice tel 32 43 43 110 www orno pl PRODUCENT DWURODZINNY ZESTAW DOMOFONOWY MIZAR MULTI RFID INSTRUKCJA OBS UGI I MONTA U Model OR DOM AT 930 W...

Page 2: ...znego i elektronicznego a co za tym idzie potencjalnym wytw rc niebezpiecznego dla ludzi i rodowiska odpadu z tytu u obecno ci w sprz cie niebezpiecznych substancji mieszanin oraz cz ci sk adowych Z d...

Page 3: ...acisn kr tko przycisk 5 na unifonie 6 OBS UGA 1 Programowanie brelok w zbli eniowych Urz dzenie wyposa one jest w funkcj otwierania wej cia za pomoc specjalnego breloka zbli eniowego Przygotuj dwa bre...

Page 4: ...tworach 3 Przy daszek w miejscu instalacji 4 Przykr ruby mocuj ce 5 Za kaset zewn trzn Monta natynkowy ciana ciana 4 SCHEMAT POD CZENIA 4 1 Schemat pod czenia zestawu z elektrozaczepem rys 5 Schemat p...

Page 5: ...Sp z o o ul Rolnik w 437 44 141 Gliwice tel 32 43 43 110 www orno pl PRODUCER TWO FAMILY INTERCOM SYSTEM MULTI RFID MISAR INSTALLATION AND OPERATION MANUAL Model OR DOM AT 930 W INSTALLATION AND OPER...

Page 6: ...n the other hand used equipment is valuable material from which we can recover raw materials such as copper tin glass iron and others The weee sign placed on the equipment packaging or documents attac...

Page 7: ...k to the visitor To open the gate remotely while talking to the external panel shortly press button 5 on the uniphone 6 OPERATION 1 Programming of proximity tags The device is equipped with a function...

Page 8: ...the mounting screws in the prepared holes 3 Put the protective cover in the place of installation 4 Tighten the mounting screws 5 Put the outer cassette on Surface mounting wall wall 4 WIRING DIAGRAM...

Page 9: ...C Sp z o o ul Rolnik w 437 44 141 Gliwice tel 32 43 43 110 www orno pl HERSTELLER ZWEI FAMILIEN SPRECHANLAGE MULTI RFID MISAR BEDIENUNGS UND MONTAGEANLEITUNG Model OR DOM AT 930 W BEDIENUNGS UND MONTA...

Page 10: ...ensch und Umwelt aufgrund des Vorhandenseins von gef hrlichen Stoffen Gemischen und Komponenten in den Ger ten gef hrlich sind Andererseits sind Altger te ein wertvoller Rohstoff aus dem Rohstoffe wie...

Page 11: ...Proximity Tags Das Ger t ist mit der Funktion ausgestattet den Eingang mit einem speziellen Schl sselanh nger zu ffnen Bereiten Sie zwei Schl sselanh nger vor rot und grau Einer von ihnen RESET KEY ro...

Page 12: ...montiert werden soll 2 Setzen Sie die Montageschrauben in die vorbereiteten L cher 3 Bringen Sie die Schutzschirm am Installationsort an 4 Ziehen Sie die Montageschrauben fest 5 Setzen Sie die u ere...