4
5
1. Drill 2 holes in the wall and place mounting screws in them.
2. Connect the cables to the connection sockets on the back
of the uniphone according to the connection diagram.
3. Fix the back of the uniphone to the wall mounted screws.
4. Hang up the handset on the base.
5. Connect the power supply to 230VAC, 50Hz.
The correct location of the external panel ensures comfortable device operation. It is recommended to
experimentally choose the best possible location for the device prior to drilling the mounting holes.
To do this, do not
place the external panel and the uniphone in the same room, as feedback may form.
The external panel is suitable for surface mounting.
3.1. Installation of external panel
3.2. Installation of the uniphone (indoor unit)
The set does not include an electric strike and automatic gate control unit!
fig. 3 Installation of the external panel
fig. 4
1. Drill two holes in the wall/post where the external panel is to be mounted.
2. Place the mounting screws in the prepared holes.
3. Put the protective cover in the place of installation.
4. Tighten the mounting screws.
5. Put the outer cassette on.
Surface mounting
wall
wall
4. WIRING DIAGRAM
4.1. Connection diagram of electric striker
fig. 5 Wiring diagram
5. SET EXTENSION
5.1. Wiring diagram of two uni phones
While designing the wiring system, take into account the suitable cross-section of cables:
2
u
p to 30 m – recommended cable XzTKMXpw
3 x
2 x 0,5 mm
2
from 30 m do 100 m – recommended cable XzTKMXpw
3 x
2 x 0,8 mm
2
The connection to the electromagnetic lock should be made with 2 x 1 mm .
Any 12 VDC electric striker with a max current draw of 500 mA can be connected to the set.
The total length of the installation must not exceed 100 meters.
The use of twisted-pair cables is absolutely not recommended.
The set does not include an electric strike and automatic gate control unit and uniphone!
fig. 6 Wiring diagram
3. INSTALLATION
Do not make any connections if the device is connected to a 230 V network!
Failure to follow these instructions may result in damage to the appliance!
External panel
Unifone 1
Unifone 2
electric
gate
control
stricke