The intercom set is designed for installation in two-family buildings, companies, schools, kindergartens, hospitals,
etc. It enables remote conversation between the external panel and the uniphone and direct control of the
electromagnetic strike and gate.
The most important features of the intercom:
- external panel suitable for surface mounting (protective cover included);
- proximity tag reader (8 user key rings and 2 administrator key rings included);
- ring tone volume adjustment;
- direct control of the electric striker;
- additional gate control;
- intercom function after using additional uniphone;
- possibility of expanding with an additional uniphone.
1. Microphone
2. Call button
3. Loudspeaker
1. Loudspeaker
2. Microphone
3. Intercom button
4. Gate opening button
5. Door/wicket opening button
6. Power supply socket
7. Ring tone volume adjustment
8. Socket for gate automation
9. Socket for external panel
10. Socket for additional uniphone
fig. 1 Construction of the external panel
fig. 2 Construction of the uniphone
2.2 Construction of the uniphone - internal unit
1. CHARACTERISTICS AND DESTINATION
2.1. Construction of the external panel
1. Reset/programming
key rings
6
Pressing the call button on the external panel (2) is indicated by the ringing tone on the uniphone.
When you pick up the handset, you can talk to the visitor.
To open the gate remotely, while talking to the external panel, shortly press button (5) on the uniphone.
6. OPERATION
1. Programming of proximity tags
The device is equipped with a function of opening the entrance with a special key ring.
Prepare two key rings - red and grey. One of them - RESET KEY (red) - deletes the active user key ring, the other -
ADDING KEY (grey) - programs user key rings. Make sure to describe them correctly.
When the intercom is on, press the RESET button on the back of the external panel, you will hear beep 6-times.
Put the red key ring on the reader area, you will hear beep 6-times. Then put the grey key ring on the reader area
until you hear a single, long beep. In this way the ADDING and RESET key rings will be programmed.
Adding a user:
To add a user, first put the ADDING key ring on the reader (you will hear beep 4-times) and then the key ring you
want to add. Wait about 10 seconds (you will hear single beep). The key ring will be programmed and single beep
will be heard during its use. The device supports RESET and ADDING key rings and up to 10 user key rings. It will
not be possible to add more.
RESET key rings:
Put the RESET KEY in the reader area, you will hear beep 4-times, this will delete all used key rings. Then put the
ADDING key on the reader to program new key rings. If no action is performed after applying the RESET key within
10 seconds, the key rings will remain programmed and will work as before.
7. OPERATION OF RFID READERS