INSTALLATION AND OPERATING INSTRUCTIONS

KU Pressure Switches

Construction:

KU series pressure switches are housed in pressed steel powder coated enclosure and are recommended for panel mounting or indoor 
service. The repeat accuracy is better than +/-1.5 % FSR.  Pressure port is 1/4” BSPM standard.

Principle of Operation:

The pressure in the pressure capsule is converted into force by means of a reinforced rubber diaphragm and a calibrated piston, which is 
balanced by a compression spring from above. When the force generated by the pressure in the pressure capsule exceeds/falls beyond 
the balancing spring force, an electrical element is actuated through a bell crank lever mechanism for accurate switching.

Please use the pressure switch well within the pressure and also the electrical parameters

Mounting

The pressure switches can be mounted in any direction.
a) Pressure switches can be mounted directly in case the mounting is rigid.
b) For panel mounting, Please use M4 bolts of appropriate length through the mounting holes . If the equipment is subject to vibration, 

please use rubber washers / pads between the panel and the switch.

Connect  the  pressure  tubing  to  the  pressure  port. The  pressure  port  size  is  generally  1/4"  B.S.P.  Male,  unless  specially  ordered 
otherwise. Other sizes can be obtained via adaptors.

Electrical Connections

Please use electrical loads well 
within the limits specified for the 
microswitch.                                       

Wiring:

Please refer figure 2.
a) Remove the cover.
b) Pass the cable through the cable 

bush  (usually  provided  with  the 
switch) and connect the wiring as 
per the wiring diagram.

The wiring code is as per the details 
given below.

Terminal 1 : (C) Common
Terminal 2 : (NC) Normally Closed
Terminal 3 : (NO) Normally Open

Please disconnect supply before wiring the switch, or removing the wiring. The cover should not be removed, if the supply is on.

APPROX. DIMENSIONS IN

mm

inches

INSTALLATION DRAWING

Fig 1.1

(0

.9

0)

23

Pressure Port

(3.26)

83

(0.35)

9

17

.5

(0

.6

8)

33

.5

(1

.3

1)

12

(0

.4

7)

(0.94)

24

1/4" BSP(M)

Cable Entry

12

.5

(0

.4

9)

6

0

.5

(2

.3

8

)

Ø5, Mtg. Holes, 3 Nos.

(0.19)

Set Screw

Differential Screw

(1.75)

44.5

(0.82)

21

9

7

.5

(3

.8

3

)

Fig. 1.2

Z

2

3

1

Reviews: