background image

Orion

®

 Guide Scope 

Mounting Plate

#7382

These assembly instructions assume you are using optional guide 
scope tube rings that come with their own mounting screws, such 
as the Orion 80mm guide scope tube rings. You will need a 10mm 
wrench or small adjustable crescent wrench to attach the guide 
scope mounting plate. 
Attach the guide scope tube rings to the top of the guide scope 
mounting plate. The top of the mounting plate is the side with the 
groove down the center. If you are using a long-tube guide scope 
(such as the Orion 80mm Guide Scope) then use the non-recessed 
holes near the ends of the mounting plate to attach the tube rings 
(Figure 1). If you are using a short-tube guide scope (such as the 
Orion ShortTube 80mm), then use the non-recessed holes near 
the middle of the mounting plate. Using the two hex-head screws 
that come with the tube rings, push the bolts up through the mount-
ing plate and thread them into the threaded holes on the guide 
scope tube rings. Tighten the bolts with the wrench.
Attach the guide scope mounting plate to the tube rings on your 
telescope. Use the two hex head screws that come with the plate 
to do this. You will need to remove the piggyback camera adapter 
from the top of the telescope tube ring, if one is installed. There 
are two sets of recessed holes; these holes will match up with the 
spacing of the telescope tube rings on the Orion SkyView Pro and 
Atlas mounts. If you have another mount, you may need to drill 
new holes in the plate to accommodate the spacing of the tube 

rings. Push the screws through the plate from the top and thread 
them into the holes on top of the telescope tube rings. Use the 
wrench to tighten the screws. You may also need to use different 
screws if you are using non-Orion tube rings.
The  guide  scope  mounting  plate,  with  guide  scope  tube  rings 
attached, is now ready to be used with a guide scope for astropho-
tography. Unthread all alignment thumbscrews on the guide scope 
tube rings until they are flush with the inside of the inside of the 
rings before inserting the guide scope. Tighten the six guide scope 
alignment thumbscrews equally until the guide scope is secure.

Figure 1.

IN 216 Rev B 09/03

Customer Support (800) 676-1343

Email: [email protected]

Corporate Offices (831) 763-7000
89 Hangar Way, Watsonville, CA 95076

Providing Exceptional Consumer Optical Products Since 1975

One-Year Limited Warranty

This Orion Guide Scope Mounting Plate is warranted against defects in materials or workmanship for a period of 
one year from the date of purchase. This warranty is for the benefit of the original retail purchaser only. During this 
warranty period Orion Telescopes & Binoculars will repair or replace, at Orion’s option, any warranted instrument 
that proves to be defective, provided it is returned postage paid to: Orion Warranty Repair, 89 Hangar Way, 
Watsonville, CA 95076. If the product is not registered, proof of purchase (such as a copy of the original invoice) 
is required.
This warranty does not apply if, in Orion’s judgment, the instrument has been abused, mishandled, or modified, 
nor does it apply to normal wear and tear. This warranty gives you specific legal rights, and you may also have 
other rights, which vary from state to state. For further warranty service information, contact: Customer Service 
Department, Orion Telescopes & Binoculars, 89 Hangar Way, Watsonville, CA 95076; (800) 676-1343.

Recessed holes

Short tube holes

Long tube holes

Reviews: