TGPS-9164GT-M12 Series User
Manual
ORing Industrial Networking Corp
148
table. Note that VeriPHY diagnostics is only accurate for cables 7 - 140 meters long. 10 and
100 Mbps ports will be disconnected while running VeriPHY diagnostics. Therefore, running
VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until
VeriPHY is completed
.
Label
Description
Port
The port where you are requesting VeriPHY Cable Diagnostics
Cable Status
Port: port number
Pair: the status of the cable pair
Length: the length (in meters) of the cable pair
5.10.6 SFP Monitor
SFP modules with DDM (Digital Diagnostic Monitoring) function can measure the temperature
of the apparatus, helping you monitor the status of connection and detect errors immediately.
You can manage and set up event alarms through DDM Web interface.