Specifications
176
7 R
ef
2-2
Product specifications
AC power input driver
Driver model
AZD-APN
AZD-CPN
Main power
supply
Input voltage
Single-phase
100-120 VAC −15 to +6 %
50/60 Hz
•
Single-phase
200-240 VAC −15 to +6 %
50/60 Hz
•
Three-phase
200-240 VAC −15 to +6 %
50/60 Hz
Input current
2.7 to 6.4 A *1
Single-phase: 1.6 to 3.9 A *1
Three-phase: 1.0 to 2.3 A *1
Control power
supply
Input voltage
24 VDC±5 % *2
Input current
0.25 A (0.5 A) *3
Interface
Pulse input
•
Number of input points: 2, photocoupler
•
Maximum input pulse frequency
Line driver output of host controller: 1 MHz (duty cycle 50 %)
Open-collector output of host controller: 250 kHz (duty cycle
50 %)
Control input
Number of input points: 6, photocoupler
Pulse output
Number of output points: 2, line driver
Control output
Number of output points: 6, photocoupler/open collector
Power removal signal input
Number of input points: 2, photocoupler
Power removal monitor output
Number of output point: 1, photocoupler/open collector
Field network
PROFINET
*1 The input current varies depending on the motor combined. Check on p.29.
*2 When an electromagnetic brake motor is used, the input voltage is 24 VDC±4 % if the wiring distance between the
motor and the driver is extended to 20 m (65.6 ft.) using our cable.
*3 The value in parentheses ( ) is the one when the electromagnetic brake motor is connected. The
AZM46
type is
0.33 A.
DC power input driver
Driver model
AZD-KPN
Main power
supply
Input voltage
•
24 VDC±5 %
•
48 VDC±5 %
Input current
0.4 to 3.3 A *1
Control power
supply
Input voltage
24 VDC±5 % *2
Input current
0.15 A (0.4 A) *3
Interface
Pulse input
•
Number of input points: 2, photocoupler
•
Maximum input pulse frequency
Line driver output of host controller: 1 MHz (duty cycle 50 %)
Open-collector output of host controller: 250 kHz (duty cycle
50 %)
Control input
Number of input points: 6, photocoupler
Pulse output
Number of output points: 2, line driver
Control output
Number of output points: 6, photocoupler/open collector
Power removal signal input
Number of input points: 2, photocoupler
Power removal monitor output
Number of output point: 1, photocoupler/open collector
Field network
PROFINET
*1 The input current varies depending on the motor combined. Check on p.66.
*2 When an electromagnetic brake motor is used, the input voltage is 24 VDC±4 % if the wiring distance between the
motor and the driver is extended to 20 m (65.6 ft.) using our cable.
*3 The value in parentheses ( ) is the one when the electromagnetic brake motor is connected. The
AZM46
type is
0.23 A.
Summary of Contents for aSTEP AZ Series
Page 120: ...120 4 PROFINET communication...
Page 172: ...172 6 Troubleshooting...