Example of execution for operation
112
4 PR
OFINE
5-2
Continuous operation
As an example, this section explains how to perform the following continuous operation.
z
Setting example
•
Operation data number: 0
•
Rotation direction: Forward direction
•
Other settings: Initial values
Speed
FW-POS
ON
OFF
Time
0
z
Operation processing flow
Descriptions are given using the host controller as the subject.
1. Check the READY has been turned ON.
2. Set the following operation data to turn the FW-POS ON.
Continuous operation is started.
•
Output (host controller
→
driver)
Byte
Description
Setting value
Note
2, 3
Operation data number selection
0
Selects the operation data No.0.
3. To stop continuous operation, turn the FW-POS OFF.
The motor decelerates to a stop.