Installation method for Air Control Louver
Use the louver if airflow must be controlled in a certain direction,
such as spot cooling.
The louver must be installed in the specified direction. Align the
projections on the louver with the holes in the blower outlet, and
affix the louver using the supplied screws.
Installation dimensions [Unit: mm (in.)]
25 (0.98) 10.5 (0.41)
3 (0.12)
4×Ø5.5
(Ø0.217)
40 (1.57)
L1 L2 L3
74 (2.90)
80 (3.15)
Applicable
model
L1
L2
L3
MBS18-
118 (4.65)
105 (4.13)
83 (3.27)
MBS20-
134 (5.28)
120 (4.72)
95 (3.74)
z
Rotational direction and air orientation
Air flow
Rotation
Wiring
Single-phase
z
MBS
-BH
,
MBS
-BWH
,
MBS
-DH
,
MBS
-DWH
Black
White
Green/Yellow
Grounding
Power cable
L
N
Three-phase
z
MBS
-TH
,
MBS
-TWH
Red
White
Black
Green/Yellow
Power cable
L1 (R)
L2 (S)
L3 (T)
Grounding
z
Power supply connector pin assignments
Single-phase
Three-phase
Black (1)
White (2)
None (3)
Green/Yellow (4)
Red (1)
White (2)
Black (3)
Green/Yellow (4)
Projection
Projection
z
Power cable connector housings/contacts
Manufacturer: TE Connectivity
Housing model number: 350779-1
Contact model number: 350536-1
Poles: 4
Applicable minimum lead wire size: AWG18 (0.75 mm
2
)
Overheat protection
The fan uses a thermal protector for overheat protection. Once the
temperature reaches a specified level, the internal thermal protector
that has an automatic-return feature is triggered to stop the fan
operation.
Be sure to turn off the power when checking the thermal protector.
Operating temperature of thermal protectors
Open (Power OFF) .........130±5 °C (266±9 °F)
Close (Power ON) ..........82±15 °C (179.6±27 °F)