background image

3

 

z

Installation method for Air Control Louver

Use the louver if airflow must be controlled in a certain direction, 
such as spot cooling.
The louver must be installed in the specified direction. Align the 
projections on the louver with the holes in the blower outlet, and 
affix the louver using the supplied screws.

Installation dimensions [Unit: mm (in.)]

25 (0.98) 10.5 (0.41)

3 (0.12)

4×Ø5.5

(Ø0.217)

40 (1.57)

L1 L2 L3

74 (2.90)

80 (3.15)

Applicable 

model

L1

L2

L3

MBS18-

118 (4.65)

105 (4.13)

83 (3.27)

MBS20-

134 (5.28)

120 (4.72)

95 (3.74)

 

z

Rotational direction and air orientation

Air flow

Rotation

Wiring

 

„

Single-phase

 

z

MBS

-BH

MBS

-BWH

MBS

-DH

MBS

-DWH

Black

White

Green/Yellow

Grounding

Power cable

L
N

 

„

Three-phase

 

z

MBS

-TH

MBS

-TWH

Red 

White 

Black 

Green/Yellow

Power cable

L1 (R)
L2 (S)
L3 (T)

Grounding

 

z

Power supply connector pin assignments

Single-phase

Three-phase

Black (1)

White (2)

None (3)

Green/Yellow (4)

Red (1)

White (2)

Black (3)

Green/Yellow (4)

Projection

Projection

 

z

Power cable connector housings/contacts

Manufacturer: TE Connectivity
Housing model number: 350779-1
Contact model number: 350536-1
Poles: 4
Applicable minimum lead wire size: AWG18 (0.75 mm

2

)

Overheat protection

The fan uses a thermal protector for overheat protection. Once the 
temperature reaches a specified level, the internal thermal protector 
that has an automatic-return feature is triggered to stop the fan 
operation. 
Be sure to turn off the power when checking the thermal protector.

Operating temperature of thermal protectors
Open (Power OFF) .........130±5 °C (266±9 °F)
Close (Power ON) ..........82±15 °C (179.6±27 °F)