Installing the non-guide type
▌
18
6-3
Installation method
The actuator can be installed in any direction.
Install the actuator onto an appropriate metal flat mounting plate [thickness approximately
5 mm (0.2 in.) or more] having excellent vibration resistance and heat conductivity. If a
high accuracy is required, design the thickness of the mounting plate in consideration of
installation conditions such as load condition, rigidity, vibration, and others.
A mounting plate is provided as an accessory.
Component parts design
The following shows the recommended design dimension of component parts and jigs
required for when the actuator is installed.
z
Movable plate
Design a screw shaft mounting hole (øC) of the movable plate in consideration of a margin so
that the stacking tolerances of parts can be adjusted.
B
A
0.02 (0.0008)
B
0.01 (0.0004)
A
øR *
øC
øR *
* They are needed when the accuracy of component parts is not enough to perform
centering.
Model
When centering is possible
When centering is difficult
øC
øC
øR
DRSM42
4.5 (0.177)
5 (0.20)
4 (0.16)
DRSM60
9 (0.354)
9 (0.35)
6 (0.24)
Unit: mm (in.)