Oregon Scientific Starck PS-M06 User Manual Download Page 1

Full Weather Station with Radio-Controlled
Clock, Projection and AM/FM Radio
(Model #: PS-M06 / PS-M06U)

User Manual

PS M06 English Cover

7/1/03, 1:52 AM

1

Summary of Contents for Starck PS-M06

Page 1: ...Full Weather Station with Radio Controlled Clock Projection and AM FM Radio Model PS M06 PS M06U User Manual PS M06 English Cover 7 1 03 1 52 AM 1...

Page 2: ...odes 9 Change settings 9 Remote unit setup 9 Clock 10 Alarm 11 Calendar 12 Moon phase 13 Barometer 13 Weather forecast 15 Temperature humidity 15 Radio 18 Backlight 19 Projector 20 Reset system 21 Saf...

Page 3: ...o PS M06 PS M06U This powerful device bundles time keeping alarm indoor and wireless outdoor temperature and humidity monitoring weather forecasting projection and digital tuned AM FM radio into a sin...

Page 4: ...3 EN PRODUCT OVERVIEW TOP VIEW DESCRIPTIONS 1 Snooze Light button 12 19 20 21 2 Light sensor 19 3 Projection lens 20 2 1 3 PS M06 English R19 7 16 03 1 05 PM 3...

Page 5: ...ESCRIPTIONS 1 Low battery icon 8 2 Clock 10 3 Barometer 13 4 Weather forecast 15 5 Moon phase 13 6 Calendar 12 7 Temperature and humidity 15 8 Alarm 11 9 Radio 18 1 2 3 4 5 6 7 8 9 PS M06 English R19...

Page 6: ...ctivate alarm 12 6 Channel switch remote unit 16 7 Radio turn radio or radio alarm on off 12 18 8 Station select a preset station 18 9 Tuning select AM FM band 18 10 Sleep activate Sleep Timer 19 11 D...

Page 7: ...PTIONS 1 Battery compartment 8 2 Backlight switch 19 3 Reset button 8 21 4 Light sensitivity knob 20 5 Headphone jack 19 6 DC power input jack 8 7 Antenna 18 AC power adapter not shown NOTE 3 1 4 2 6...

Page 8: ...play 15 17 2 Low battery icon 8 3 Humidity Trend Comfort Level display 15 17 4 C F switch 9 5 Channel switch 9 6 Reset button 8 21 7 Battery compartment 8 8 Wall mount hole 9 Battery compartment lid 1...

Page 9: ...u close the lid press the RESET button with the point of a blunt object such as a ball point pen Insert the batteries in the remote unit before you set up the main unit Do not use rechargeable batteri...

Page 10: ...r 1 2 or 3 switches are located in the battery compartment and should be set prior to installation Additional remote units sold separately If you are using more than one remote unit be sure to select...

Page 11: ...may need to experiment with various locations to get the best reception CLOCK This product can automatically synchronize the date and time with official time keeping organizations in Frankfurt German...

Page 12: ...3 Select the 12 24 hour format hour and minute Press UP or DOWN to change the setting Press SELECT to confirm ALARM When activated the Melody Alarm starts quietly then gradually becomes louder It shut...

Page 13: ...isable the alarm for 8 minutes The alarm icon will blink while Snooze is activated TO TURN THE ALARM OFF OR ON Press RADIO to turn the radio alarm off Press any other button to turn the melody alarm o...

Page 14: ...Press SELECT until the Calendar Area flashes Then press UP or DOWN to change the date and view the corresponding moon phase BAROMETER This product tracks barometric pressure changes over the past 24 h...

Page 15: ...last 24 hours history SET UNIT AND ALTITUDE You can set the unit of measurement mb hPa or inHg and altitude Setting the altitude allows the product to take more accurate barometric measurements 1 Pre...

Page 16: ...tton you can check the current indoor or outdoor temperature humidity percentage comfort level trend and record measurements Outdoor measurements are collected by the remote unit Temperature is given...

Page 17: ...e previous measurements from the memory SELECT REMOTE UNIT CHANNEL While in the Temperature Humidity Mode press CHANNEL to switch between CH 1 2 or 3 or press and hold CHANNEL for 2 seconds to enter A...

Page 18: ...d arrow for the last 30 minutes always displays Indoor and outdoor temperature and humidity trends are shown separately Zone Comfort 20 25 C 68 77 F 40 70 Wet Any 70 Any Dry 40 RelativeHumidity Temper...

Page 19: ...he best reception TURN THE RADIO ON OR OFF Press the RADIO button VOLUME Press UP or DOWN There are 8 volume levels SWITCH AM FM BAND Press TUNING to enable auto tuning Press again to switch AM FM ban...

Page 20: ...headphones for stereo quality radio listening BACKLIGHT Press SNOOZE LIGHT to illuminate the backlight for 5 seconds CONTINUOUS BACKLIGHT The AC power adapter must be plugged in to use this feature 8...

Page 21: ...e and alarm status at night The maximum projection range is 2 meters 6 feet The image gets larger the farther you display it PROJECT TIME ALARM STATUS In a darkened room press SNOOZE LIGHT to display...

Page 22: ...he main and remote units Press these buttons with the tip of a blunt object such as a ball point pen whenever you change the batteries or whenever performance is not behaving as expected e g unable to...

Page 23: ...tamper with the internal components Do not mix new and old batteries or batteries of different types Do not use rechargeable batteries with this product Remove the batteries if storing this product f...

Page 24: ...AC power adapter Check the BACKLIGHT switch 8 19 TROUBLESHOOTING Check here before contacting our customer service department Radio Problem Symptom Remedy Select radio format 18 Reception is poor sta...

Page 25: ...t 14 Problem Symptom Remedy Clock Cannot auto synchronize 1 Remove batteries 2 Press reset All memory items will return to default 3 Replace batteries 4 Place clock near window away from electrical de...

Page 26: ...battery Temperature Unit C or F Range Main unit 5 C to 50 C 23 F to 122 F Remote Unit 20 C to 60 C 4 F to 140 F Resolution 0 1 C 0 2 F Comfort 20 C to 25 C 68 F to 77 F see also Relative humidity Memo...

Page 27: ...r radio 2 minute crescendo melody only Snooze 8 minutes melody only Barometer Unit mb hPa or inHg Range 500 to 1050 mb 14 77 to 31 01 inHg Resolution 1 mb 0 03 inHg Altitude 100 to 2500 meters 328 to...

Page 28: ...es Stereo sound not supplied Antenna Wire Projector Display Current time alarm status Rotation 180 and image flip Focusing Manual Projection 5 second or continuous Power Main unit 4 x UM 3 AA 1 5V alk...

Page 29: ...our new product and other Oregon Scientific products such as digital cameras hand held organizers health and fitness gear and weather stations The website also includes contact information for our cus...

Page 30: ...f the R TTE Directive applied standard s ETSI EN 301 489 1 3 Ver 1 4 1 2002 08 Safety of information technology equipment Article 3 1 a of the R TTE directive applied standard s EN 60950 2000 Addition...