background image

EN

6

BACK

1

2
3
4

5
6

7

8

1.

Wall mount (recess hole)

2.

CHANNEL

 switch

3.

RESET

4.

°

C/

°

F

 switch

5.

SEARCH

 button

6.

EU/UK

 radio signal format switch

7.

Battery compartment

8.

Fold-out stand

FOLD-OUT STAND

1.

Fold-out the stand.

2.

Lock it into place.

AWS888 English r23 op

10/14/03, 4:32 PM

6

Black

Summary of Contents for AWS888

Page 1: ...e 13 Turning alarm on off 13 Weather forecast mode 13 Temperature pressure hygro mode 14 Barometer display 14 Thermo hygro memory 14 Clear MIN MAX records 15 Current thermo hygro display 15 Auto scan function 15 Comfort zone 15 Trends 15 System setting mode 16 System settings 16 Volume 16 Language 16 Silence mode 16 Auto rotation frequency 16 Sleep mode 16 Auto rotation display mode 16 Clock alarm...

Page 2: ... contains practical step by step instructions as well as technical specifications and warnings you should know In this box you will find Main unit Remote sensor Batteries AC adaptor PRODUCT OVERVIEW MAIN UNIT TOP VIEW 1 Photo Sensor Cell 2 SNOOZE 3 CHANNEL 4 HOME return to MAIN MENU The Photo Sensor Cell can adjust the backlight automatically In a darker room the cell will decrease the screen s br...

Page 3: ...3 EN FRONT VIEW 1 Colour display 2 Increase decrease setting 3 ENTER select option BACK VIEW BATTERY COMPARTMENT 1 RESET 2 SEARCH 1 2 3 1 2 AWS888 English r23 op 10 14 03 4 32 PM 3 Black ...

Page 4: ...nclude the RF function such as THGR228N THGR238N 3 channel sensor THGR328N 5 channel sensor NOTE LCD DISPLAY HOME MENU 1 Weather Forecast Display Mode 2 Clock Alarm Display Mode 3 Temperature Pressure Hygro Display Mode 4 Auto Rotation Display Mode 5 General Setting Mode 6 System Setting Mode Sub menus will be described within the related sections 1 2 3 4 5 6 AWS888 English r23 op 10 14 03 4 32 PM...

Page 5: ...s indicator 3 Ventilation duct 1 2 3 LCD 1 RF clock reception 2 Channel no 3 Low battery indicator 4 Time 5 Temperature C or F 6 Relative humidity 7 Temperature Humidity reading 1 2 3 5 6 4 7 AWS888 English r23 op 10 14 03 4 32 PM 5 Black ...

Page 6: ...ecess hole 2 CHANNEL switch 3 RESET 4 C F switch 5 SEARCH button 6 EU UK radio signal format switch 7 Battery compartment 8 Fold out stand FOLD OUT STAND 1 Fold out the stand 2 Lock it into place AWS888 English r23 op 10 14 03 4 32 PM 6 Black ...

Page 7: ...tor should power the main unit NOTE REMOTE UNIT SET UP Up to 5 remote units can be used with this product to monitor outdoor temperature and humidity The remote unit included in this package is used to receive radio frequency signals for the radio controlled clock and to measure temperature and humidity The measurement unit C or F and channel number 1 2 3 4 or 5 switches are located in the battery...

Page 8: ...STALLATION Mount the remote unit on a flat surface using the recess holes on the back of the unit For best results Insert the batteries and select the measurement unit and channel number first Place the unit out of direct sunlight and moisture Do not place the remote unit more than 30 meters 98 feet from the main indoor unit Position the unit so that it faces the main indoor unit Minimize obstruct...

Page 9: ...t when the main unit is reset GENERAL SETTINGS MODE All settings and display options for this product are accessible from the MAIN MENU NAVIGATING THROUGH MAIN MENU To access MAIN MENU from any screen press HOME Press or to highlight a desired option then press ENTER to activate it CHANGING SETTINGS 1 Press or to highlight the option you wish to change 2 Press ENTER to select it 3 Use the UP or DO...

Page 10: ... format and Analog Digital or Classic Clock display format RF CLOCK Set Auto synchronization on or off 2nd ZONE OFFSET Set 2nd zone time Exit Return to previous page Press to choose a setting the selected item will flash Press ENTER to start making adjustments Press to change values Press ENTER to confirm changes TIP Press HOME to return to MAIN MENU 2nd ZONE OFFSET You can offset current local ti...

Page 11: ...nging Press ENTER begin adjusting values Press change values Press ENTER to confirm changes A will indicate that an alarm is active ALARM TYPES DAILY AND WEEKDAYS ALARM DAILY alarm can be set to go off once at the set time everyday of the week WEEKDAYS alarm will go off at the set time every weekday of the week i e Monday to Friday only SNOOZE Press SNOOZE to temporarily disable the alarm for 8 mi...

Page 12: ...G mode Temperature Select C or F temperature units Barometric Unit Select Mb hPa or inHg pressure units Altitude Set the compensated altitude 100m to 2500m default 0m Exit Return to previous page In this mode you can set Press to select the value you wish to change then press ENTER Adjust the values using press ENTER to keep them ALTITUDE COMPENSATION FUNCTION Set the altitude corresponding to how...

Page 13: ...ately without going into the setting mode 1 Press CHANNEL to select alarm 1 or 2 2 Press to switch alarm on or off 3 Press ENTER or wait 10 seconds to confirm the changes TIP You can change the look of your display WEATHER FORECAST MODE This product forecasts the next 12 to 24 hours of weather within a 30 to 50 km 19 31 mile radius with 70 to 75 percent accuracy A weather forecast with sound effec...

Page 14: ...ors To display a MIN MAX reading select a channel by pressing CHANNEL 1 1 hour ago 3 3 hours ago 6 6 hours ago 12 12 hours ago 24 24 hours ago The weather forecast symbol is updated every 15 minutes TEMPERATURE PRESSURE HYGRO MODE With the press of a button you can check the current indoor or outdoor temperature relative humidity comfort level trend and record measurements Outdoor measurements are...

Page 15: ...each channel will be displayed for 4 seconds before changing to the next channel To start auto scan press and hold CHANNEL until you hear a beep press CHANNEL again to exit auto scan mode COMFORT ZONE The indoor and outdoor comfort zones are always shown they display the relationship between temperature and humidity Zone Temperature Relative Humidity Any 70 20 25 C 68 77 F 40 70 Any 40 TRENDS For ...

Page 16: ...isplay turns on when the alarm goes off or a button is pressed AUTO ROTATION DISPLAY MODE When this function is enabled the unit will automatically switch between the following modes Weather forecast Clock alarm Temperature pressure Hygro You can adjust the speed at which each mode is displayed via the auto rotation frequency setting DOWN UP STEADY Trends SYSTEM SETTING MODE In this mode you can c...

Page 17: ...requency link with remote unit or automatic clock etc After resetting the system all system information will be erased and returned to factory defaults The main unit will also check battery condition NOTE NOTE Analog Digital Classic DEFAULT SETTINGS Date 1 1 2003 Time 00 00 00 24 hour format or 12 00 00 am 12 hour format Clock display Time second display mode Daily weekly alarm Alarm disabled Slee...

Page 18: ... handled properly Observe the following guidelines Never immerse the unit in water This can cause electrical shock and damage the unit Do not subject the main unit to extreme force shock or fluctuations in temperature or humidity Do not tamper with the internal components Do not mix new and old batteries or batteries of different types Do not use rechargeable batteries with this product Remove the...

Page 19: ...ngs SPECIFICATIONS Main unit dimensions L x W x H 165 x 124 x 39mm 6 5 x 4 88 x 1 54 inches Weight 432g with batteries Remote unit dimensions L x W x H 70 x 24 5 x 116mm 2 76 x 0 96 x 4 57 inches Weight 156g with batteries Temperature Unit C or F Indoor Range 5 C to 50 C 23 F to 122 F Outdoor Range 20 C to 60 C 4 F to 140 F Resolution 0 1 C 0 2 F Comfort 20 C to 25 C 68 F to 77 F Memory Minimum ma...

Page 20: ...e you need to reach us Barometer Unit mb hPa or inHg Range 500 to 1050 mb 14 77 to 31 01 inHg Resolution 1mb 0 03 inHg Altitude 100 to 2500 meters 328 to 8202 feet Display Sunny partly cloudy cloudy rainy snowy Remote unit RF frequency 433 MHz Range 30 meters 98 feet with no obstructions Transmission every 1 minute Channel No 1 2 3 4 or 5 Unit C or F Radio controlled clock Synchronization Auto or ...

Page 21: ...tter module TX 05 and complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directives if used for its intended use and that the following standard s has have been applied Radio frequency spectrum Article 3 2 of the R TTE Directive applied standard s ETSI EN 300 220 3 Ver 1 1 1 2000 09 Electromagnetic compatibility Article 3 1 b of the R TTE Directive applied standard s ETSI...

Reviews: