MOBILE WELDER OC PLUS
ENGLISH
ORBITALUM TOOLS GmbH
, D-78224 Singen www.orbitalum.com
35
1. Check the stability of the gas bottle.
2. Secure the gas bottle against falling over.
3. Attach the gas hoses included in the scope of
delivery to the pressure reducer.
4. Mount the pressure reducer on the gas bottle.
5. Set the desired volume rate on the pressure
reducer.
6. Insert the free end of the gas hose (1) into the
gas inlet connection (2) on the rear of the
power supply as far as it will go.
ð
The gas hose is secured against slipping out
by the locking ring of the gas inlet connection.
Gas hose diameter AD = 6 mm
1
2
7.7
Mains connection
For detailed information on the mains input voltage, see the chapter
►
Ensure that the mains connection at the place of use complies with local regulations.
►
Ensure that only original ORBITALUM power supply cables are used for the mains connection.
►
Ensure that the electrical outlet is properly rated and grounded.
►
Check the power cable and power plug for damage before use.
WARNING
Faulty mains connection
Injury and property damage from electric shock
► Operate the welding power supply only on a single-phase 2-wire
system with grounded neutral conductor.
► A residual current device (RCD) to IEC standards with a rated resid-
ual current of max. 0.03 A or a protective isolating transformer is re-
quired on the mains side.
Summary of Contents for MOBILE WELDER OC PLUS
Page 8: ...ENGLISH MOBILE WELDER OC PLUS 8 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 20: ...ENGLISH MOBILE WELDER OC PLUS 20 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 177: ...MOBILE WELDER OC PLUS ENGLISH ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com 177 ...
Page 200: ...SPARE PARTS MOBILE WELDER OC PLUS 200 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 204: ......