
2-4
INSTALLATION
ORBAN MODEL
6.
Connect tally outputs (optional)
See the schematic on page 6-32.
The 8600Si supports two hardware tally outputs, which are NPN open-collector
and operate with respect to pin 1 (common). Therefore, the voltage applied to
the load (such as a relay or opto-isolator) must be positive. You can use the 12
VDC source on pin 25 to drive the high side of the load, taking into account the
fact that the voltage on pin 25 is current limited by a 300
Ω
resistor.
The tally outputs are protected against reverse polarity.
To avoid damaging the 8600Si, limit the current into a tally output
to 30 mA. DO NOT connect a tally output directly to a low-
impedance voltage source! The tally outputs are not protected
against this abuse and the output transistors are likely to burn out.
Note that the tally outputs have no special RFI protection. Therefore, it is wise to
use shielded cable to make connections to them.
See step 3.D) on page 2-25 for instructions on using the tally outputs.
7.
Connect to a computer
You can connect to a computer via the 8600Si’s serial connector or via an Ether-
net network. (See
Networking
Procedures and instructions for connecting to a PC are subject to development
and change. We advise you to download the latest version of this manual in pdf
format from
You can use Adobe’s .pdf reader application to open and read this file. If you do
not have the .pdf reader, it is available for free download from
See
Installing 8600Si PC Remote Control Software
8600Si Rear Panel
[See page 3-1 for a description of the 8600Si’s front panel.]
The
Power Cord
is detachable and is terminated in a “U-ground” plug (USA stan-
dard), or CEE7 / 7 plug (Continental Europe), as appropriate to your 8600Si’s Model
Number.
An
RS-232 (PC Remote) Computer Interface,
labeled
S
ERIAL
, is provided to con-
nect the 8600Si to IBM PC-compatible computers, directly or via modem, for remote
control, metering and software downloads.
A
Remote Interface Connector
allows you to connect the 8600Si to your existing
transmitter remote control or other simple contact-closure control devices. The
8600Si remote control supports user-programmable selection of up to eight opti-
cally-isolated inputs for any one of the following parameters: recalling any factory-
or user presets, tone or bypass modes, selecting stereo encoder modes (stereo,
Summary of Contents for OPTIMOD-FM 8600Si
Page 1: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Page 7: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Page 56: ......
Page 255: ...OPTIMOD FM DIGITAL OPERATION 3 89...
Page 272: ......
Page 328: ......
Page 330: ...6 28 TECHNICAL DATA ORBAN MODEL 8600Si CONTROL BOARD PARTS LOCATOR...
Page 354: ...6 52 TECHNICAL DATA ORBAN MODEL 8600Si...