![Orban OPTIMOD-FM 5700i Operating Manual Download Page 81](http://html1.mh-extra.com/html/orban/optimod-fm-5700i/optimod-fm-5700i_operating-manual_1647010081.webp)
OPTIMOD-FM DIGITAL
INSTALLATION
2-25
A)
Navigate to
Setup
>
S
ILENCE
T
HR
and set the Silence Threshold to the level be-
low which the 5700i will interpret the input as being silent.
This setting is with respect to the current analog reference level and digi-
tal reference level.
B)
Press
Next
as necessary to see the
S
ILENCE
D
LY
control. Set it to the amount of
time that the input must be below the Silence Threshold before the 5700i au-
tomatically switches to the analog input.
C)
Press
Next
as necessary to see the
A
NLG
F
ALL
-B
ACK
control. Set it to
Y
ES
if you
wish the 5700i to switch automatically from the digital to analog input when
silence is detected. Set the control to
N
O
to defeat automatic switching.
D)
Press
Next
as necessary to see the
DI
A
NLG
F-B
control. Set it to
Y
ES
if you wish
the 5700i to switch automatically from the analog to digital input when si-
lence is detected. Set the control to
N
O
to defeat automatic switching.
4.
Program Tally Outputs.
[Skip this step if you do not wish to use the tally outputs.]
See step 6 on page 2-4 for wiring instructions.
You can program the two tally outputs to indicate a number of different opera-
tional and fault conditions.
A)
Navigate to
Setup
>
N
ETWORK
R
EMOTE
>
R
EMOTE
I
NTERFACE
>
T
ALLY
1
.
B)
Program tally output #1.
To program a given tally output, press and hold the soft button associ-
ated with the output you are programming. As you turn the control
knob, the functions listed below will appear in the highlighted field.
•
Input: Analog
: Indicates that the 5700i is processing audio from its analog
input.
•
Input: Digital
: Indicates that the 5700i is processing audio from its AES3
digital input.
•
Analog Input Silent
: Indicates that the level at either or both analog in-
put channels is below the threshold set in step 3 on page 2-24.
•
AES Input Silent
: Indicates that the level at either or both digital input
channels is below the threshold set in step 3 on page 2-24.
•
AES Input Error
: Indicates that the 5700i’s AES input receiver chip has de-
tected a problem with the data being received such that the data is unus-
able. When the chip detects such an error, it automatically switches the in-
put to
A
NALOG
.
•
Sync Reference Input Error
: Indicates that the 5700i has detected a prob-
lem with the signal being received at the sync reference input such that the
Summary of Contents for OPTIMOD-FM 5700i
Page 1: ...Operating Manual OPTIMOD FM 5700i Digital Audio Processor Version 2 1 Software...
Page 7: ...Operating Manual OPTIMOD FM 5700i Digital Audio Processor Version 2 1 Software...
Page 26: ......
Page 56: ......
Page 282: ......
Page 308: ...6 26 TECHNICAL DATA ORBAN MODEL 5700i...