Return the Server to the Normal Rack Position
236
Sun Server X4-4 Service Manual • October 2015
1.
Slowly pull the server out of the rack until the slide-rails reach their stops.
2.
Inspect the attached cables for any binding or kinks.
3.
Verify that the CMA extends fully from the slide-rails.
4.
Push the server back into the rack, as described in the following sub-steps.
When the server is fully extended, you must release two sets of slide-rail stops to return the
server to the rack:
a.
Push in both green levers simultaneously and slide the server toward the
rack.
The first set of stops are levers located on the inside of each slide-rail, just behind the back
panel of the server.
The server slides in approximately 18 inches (46 cm) and stops.
Verify that the cables and the CMA retract without binding before you continue.
b.
Push the server completely into the rack until both slide-rail locks engage.
The second set of stops are the slide-rail release buttons, located near the front of each
mounting bracket. Simultaneously push both of the green slide-rail release buttons.
5.
Adjust the cable straps and CMA, as required.
Return the Server to the Normal Rack Position
This procedure decribes how to return the server to the normal rack position in preparation for
operation.
Summary of Contents for Sun Server X4-4
Page 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Page 2: ......
Page 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Page 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Page 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Page 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Page 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Page 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Page 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Page 292: ...292 Sun Server X4 4 Service Manual October 2015 ...