Install a PCIe Card Filler Panel
156
Sun Server X4-4 Service Manual • October 2015
2.
To disengage the PCIe card retaining bar, push down on the bar, move it away
from the server back wall, and lift it to an upright position.
3.
Install the PCIe card filler panel into the PCIe card slot.
4.
Return the PCIe card slot crossbar to its closed and locked position.
5.
Prepare the server for operation. See
.
HBA Reference
The six-slot storage backplane and the DVD-RW drive are connected to a low-profile SAS2
PCIe HBA (factory installed in PCIe Slot 2) by two mini SAS4I cables. The two cables are
color coded. One cable has white labels on both ends (with the designation 7044138). One
end of the cable has a single mini SAS4I connector, and the other end has two connectors (a
split end) with a mini SAS4I connector and a smaller SATA connector. The other cable has a