Displaying FRU Information
Chapter 1 • Server Diagnostics
31
1.4.3
Clearing Faults
Use the
clear_fault_action
property of a FRU to manually clear PSH diagnosed faults from
the service processor without a FRU replacement or if the service processor was unable to
automatically detect the FRU replacement.
Note -
This procedure clears the fault from the service processor but not from the host. If the
fault persists in the host, it must be manually cleared.
■
Example showing a PSH diagnosed fault being cleared manually using the
clear_fault_action
property of the FRU:
-> set /SYS/MB/CMP0/BR0/CH0/D0 clear_fault_action=True
Are you sure you want to clear /SYS/MB/CMP0/BR0/CH0/D0 (y/n)? y
Set 'clear_fault_action' to 'true'
Displaying FRU Information
Before You Begin
Use the
show
command to display information about individual FRUs in the server.
At the
->
prompt, enter the
show
command.
In the following example, the
show
command is used to get information about a memory
module (FB-DIMM).
-> show /SYS/MB/CMP0/BR0/CH0/D0
/SYS/MB/CMP0/BR0/CH0/D0
Targets:
R0
R1
SEEPROM
SERVICE
PRSNT
T_AMB
Properties:
type = DIMM
component_state = Enabled
fru_name = 1024MB DDR2 SDRAM FB-DIMM 333 (PC2 5300)
fru_description = FBDIMM 1024 Mbyte
fru_manufacturer = Micron Technology
fru_version = FFFFFF
fru_part_number = 18HF12872FD667D6D4
fru_serial_number = d81813ce
fault_state = OK