Verifying Successful Replacement of a Faulty
FB‐
DIMM
108
Sun Netra T5440 Server • September 2015
->
set /SYS keyswitch_state=Normal
Set ???ketswitch_state' to ???Normal'
e.
Switch to the system console and issue the Solaris OS
fmadm faulty
command.
#
fmadm faulty
No memory faults should be displayed.
If faults are reported, refer to the diagnostics flowchart in
diagnose the fault.
4.
Switch to the ILOM
->
command shell.
5.
Run the
show faulty
command.
■
If the fault was detected by the host and the fault information persists, the
output will be similar to the following example:
->
show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BR0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
■
If the
showfaults
command does not report a fault with a UUID, then you do
not need to proceed with the following steps because the fault is cleared.
6.
Run the
set
command.
->
set /SYS/MB/CMP0/BR0/CH1/D0 clear_fault_action=True
Are you sure you want to clear /SYS/MB/CMP0/BR0/CH1/D0 (y/n)?
y
Set 'clear_fault_action' to 'true
7.
Switch to the system console and issue the fmadm repair command with the
UUID.
Use the same UUID that was displayed from the output of the ILOM
show faulty
command.
#
fmadm repair 3aa7c854-9667-e176-efe5-e487e520