Verifying Successful Replacement of a Faulty
FB‐
DIMM
Chapter 4 • Replacing Motherboard Assembly Components
107
->
set /SYS/MB/CMP0/BR0/CH0/D0 component_state=Enabled
3.
Perform the following steps to verify the repair:
a.
Set the virtual keyswitch to diag so that POST will run in Service mode.
->
set /SYS/keyswitch_state=Diag
Set ???keyswitch_state' to ???Diag'
b.
Powercycle the system.
->
stop /SYS
Are you sure you want to stop /SYS (y/n)?
y
Stopping /SYS
->
start /SYS
Are you sure you want to start /SYS (y/n)?
y
Starting /SYS
Note -
The server takes about one minute to power off. Use the show /HOST command to
determine when the host has been powered off. The console will display
status=Powered Off
.
c.
Switch to the system console to view POST output.
->
start /SYS/console
Watch the POST output for possible fault messages. The following output is a sign that
POST did not detect any faults:
.
.
.
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
Note -
Depending on the configuration of ILOM POST variables and whether POST detected
faults or not, the system might boot, or the system might remain at the
ok
prompt. If the system
is at the
ok
prompt, type
boot
.
d.
Return the virtual keyswitch to normal mode.