A.3 Serial Ports
152
Sun Netra T5440 Server • September 2015
FIGURE A-3
Serial Management Port Pin Numbering
TABLE A-5
Serial Management RJ-45 Connector Signals
Pin
Signal Description
Pin
Signal Description
1
Request to Send
5
Ground
2
Data Terminal Ready
6
Receive Data
3
Transmit Data
7
Data Set Ready
4
Ground
8
Clear to Send
If you need to connect to the SERIAL MGT port using a cable with either a DB-9 or a DB-
25 connector, use a supplied adapter to perform the crossovers given for each connector. The
supplied RJ-45 to DB-9 and RJ-45 to DB-25 adapters are wired as described in
and
.
A.3.1.1
RJ-45 to DB-9 Adapter Crossovers
TABLE A-6
RJ-45 to DB-9 Adapter Crossovers
Serial Port (RJ-45 Connector)
DB-9 Adapter
Pin
Signal Description
Pin
Signal Description
1
RTS
8
CTS
2
DTR
6
DSR
3
TXD
2
RXD
4
Signal Ground
5
Signal Ground
5
Signal Ground
5
Signal Ground
6
RXD
3
TXD
7
DSR
4
DTR
8
CTS
7
RTS