Install the Disk Backplane Assembly
124
Sun Netra T5440 Server • September 2015
Install the Disk Backplane Assembly
1.
Unpack the replacement disk backplane assembly and place it on an antistatic
mat.
2.
Slide the disk backplane down into position.
3.
Tighten the three green captive screws.
4.
Attach the ribbon cables.
5.
Attach the SAS cable.
6.
Attach the two bus bars that secure the disk backplane in place.
7.
Perform the following tasks to bring the server back online:
■
“Install the Motherboard Assembly” on page 118
■
“Install the SCC Module” on page 113
■
“Install the System Fan Assembly (Fan Tray 0)” on page 136
■
“Install the Memory Mezzanine Assembly” on page 97
■
“Install the PCI Mezzanine Assembly” on page 88
■
“Install the SAS Expander Assembly” on page 125
■
“Install the Hard Drive Fan Assembly (Fan Tray 1)” on page 139
8.
Install the hard drives.
See
“Install a Hard Drive” on page 66
9.
Restore the OpenBoot PROM variables.
See
in
“Install the Motherboard Assembly” on page 118
.
10.
Return the server to operation.
See
Chapter 6, “Returning the Server to Operation”
4.14 Replacing the SAS Expander Assembly
This section describes how to remove and install the SAS expander assembly.