Install FB-DIMMs
104
Sun Netra T5440 Server • September 2015
FIGURE 4-21
Removing FB-DIMMs
6.
Place the FB-DIMM on an antistatic mat.
7.
to remove any additional FB-DIMMs.
8.
Install filler panels in the empty FB-DIMM slots, if you are not replacing the FB-
DIMMs right away.
Install FB-DIMMs
Caution -
Ensure that all power is removed from the server before removing or installing FB-
DIMMs or damage to the FB-DIMMs might occur. You must disconnect the power cables from
the system before performing this procedure.
1.
Unpackage the replacement FB-DIMMs and place them on an antistatic mat.
Tip -
See
“4.7 FB-DIMM Configuration Reference” on page 90
configuring the FB-DIMMs.
2.
Ensure that the ejector tabs are in the open position.
3.
Line up the replacement FB-DIMM with the connector (
).