Main Module LEDs
Main Module LEDs
No.
LED
Icon
Description
1
Service Required LED
(amber)
Indicates that service is required. POST and Oracle ILOM are two
diagnostic tools that can detect a fault or failure resulting in this
indication.
The Oracle ILOM
show faulty
command provides details about any
faults that cause this indicator to illuminate.
Under some fault conditions, individual component fault LEDs are lit in
addition to the Service Required LED.
2
Power OK LED (green)
Indicates these conditions:
■ Off – System is not running in its normal state. System power might
be off. The SPM might be running.
■ Steady on – System is powered on and is running in its normal
operating state. No service actions are required.
■ Fast blink – System is running in standby mode and can be quickly
returned to full function.
■ Slow blink – A normal but transitory activity is taking place. Slow
blinking might indicate that system diagnostics are running or that
the system is booting.
3
SPM LED
(green)
SPM
Indicates these conditions:
■ Off – AC power might have been connected to the power supplies.
98
SPARC T8-4 Server Service Manual • January 2022
Summary of Contents for SPARC T8-4
Page 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Page 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Page 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Page 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Page 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Page 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Page 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Page 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Page 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Page 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...