Determine Which DIMM Is Faulty (DIMM Fault LEDs)
Determine Which DIMM Is Faulty (DIMM Fault
LEDs)
DIMMs are cold-service components that can be replaced by customers. For the location of the
DIMMs, see
“Processor Module Components” on page 18
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause failure of server components.
1.
Consider your first steps.
■
Familiarize yourself with DIMM configuration rules.
See
“Understanding DIMM Configurations” on page 69
■
Prepare the system for service.
See
“Preparing for Service” on page 43
■
Remove the processor module containing the faulty DIMM. Place the
processor module on an ESD-protect work surface. Remove the processor
module cover.
See
“Remove a Processor Module or Processor Filler Module” on page 60
.
76
SPARC T8-4 Server Service Manual • January 2022
Summary of Contents for SPARC T8-4
Page 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Page 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Page 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Page 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Page 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Page 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Page 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Page 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Page 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Page 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...