Remove a Memory Riser
Remove a Memory Riser
This is a cold-service procedure that can be performed by a customer. Power down the server
completely before performing this procedure.
Caution -
This procedure requires that you handle components that are sensitive to ESD which
can cause server components to fail.
Note -
Your server could include a memory riser that is secured with a flat-head screw. If that is
the case, use a No. 1 flat-blade screwdriver to service that memory riser.
1.
Prepare for servicing.
See
“Preparing for Service” on page 45
2.
Identify the memory riser with the faulty DIMM by pressing the Remind button on
the air divider as shown in the following figure.
98
SPARC T8-2 Server Service Manual • June 2019
Summary of Contents for SPARC T8-2
Page 1: ...SPARC T8 2 Server Service Manual Part No E80511 04 June 2019 ...
Page 2: ......
Page 10: ...10 SPARC T8 2 Server Service Manual June 2019 ...
Page 12: ...12 SPARC T8 2 Server Service Manual June 2019 ...
Page 24: ...Server Block Diagram 24 SPARC T8 2 Server Service Manual June 2019 ...
Page 26: ...26 SPARC T8 2 Server Service Manual June 2019 ...
Page 62: ...62 SPARC T8 2 Server Service Manual June 2019 ...
Page 82: ...82 SPARC T8 2 Server Service Manual June 2019 ...
Page 110: ...110 SPARC T8 2 Server Service Manual June 2019 ...
Page 114: ...114 SPARC T8 2 Server Service Manual June 2019 ...
Page 128: ...128 SPARC T8 2 Server Service Manual June 2019 ...
Page 136: ...136 SPARC T8 2 Server Service Manual June 2019 ...
Page 146: ...146 SPARC T8 2 Server Service Manual June 2019 ...
Page 164: ...164 SPARC T8 2 Server Service Manual June 2019 ...
Page 170: ...170 SPARC T8 2 Server Service Manual June 2019 ...
Page 176: ...176 SPARC T8 2 Server Service Manual June 2019 ...
Page 182: ...182 SPARC T8 2 Server Service Manual June 2019 ...
Page 188: ...188 SPARC T8 2 Server Service Manual June 2019 ...