Environmental Specifications
■
“Physical Specifications” on page 19
■
“Environmental Specifications” on page 21
■
“Airflow Precautions” on page 22
Environmental Specifications
This topic includes these specifications that apply to both server configurations:
■
Temperature, humidity, and elevation
■
Shock and vibration
■
Acoustic
TABLE 1
Temperature, Humidity, and Elevation Specifications
Operating
Nonoperating
Description
U.S.
Metric
U.S.
Metric
Notes
Temperature
(maximum)
41 to 95°F at 0 to
3000 ft
5 to 35°C at
900m
-40 to 149°F at 0
to 3000 ft
-40 to 65°C at
900m
Decrease in maximum temperature:
above 3000 ft. (900m), 1.8°F/1000 ft
(1°C/300m)
Relative humidity
10 to 80% at 81°F 10 to 80% at
27°C
Up to 85% at
100°F
Up to 85% at
38°C
Maximum wet bulb noncondensing
Altitude
0 to 9840 ft
at 95°F
†
0 m to 3000m at
40°C
†
Up to 39,370 ft
Up to 12,000m
†
Except in China markets where regulations might limit installations to a maximum altitude of 2km.
TABLE 2
Shock and Vibration Specifications
Description
Operating
Notes
Shock
3G, 11 ms
Half-sine
Vibration (vertical)
0.15G
5 to 500 HZ swept-sine
Vibration (horizontal)
0.10G
TABLE 3
Acoustic Specifications
Description
Operating at 60%
Operating at 100%
Sound Power Level - LwAd (1 B=10 dB)
8.2 B
9.7 B
Sound Pressure Level - LpAm (energy
average of four bystander positions)
66.2 dBA
80.3 dBA
Specifications
21
Summary of Contents for SPARC T8-1
Page 1: ...SPARC T8 1 Server Installation Guide Part No E80507 03 June 2019 ...
Page 2: ......
Page 8: ...8 SPARC T8 1 Server Installation Guide June 2019 ...
Page 24: ...24 SPARC T8 1 Server Installation Guide June 2019 ...
Page 50: ...50 SPARC T8 1 Server Installation Guide June 2019 ...
Page 72: ...72 SPARC T8 1 Server Installation Guide June 2019 ...
Page 76: ...76 SPARC T8 1 Server Installation Guide June 2019 ...